Theoretical evaluation of measurement uncertainties of two-color pyrometry applied to optical diagnostics
We present a theoretical analysis of two-color pyrometry applied to optical diagnostics. A two-color pyrometer built with a single CCD is advantageous due to the simple system design. We evaluate the possibility and degree of ill-conditionness on the basis of measurement uncertainties for different measurement approaches of this two-color system. We classify measurement approaches. The corresponding ill-conditionness criterion is established. The greater the criterion value is, the worse the ill-conditioned degree of solution is. So, the optimum choice of measurement approach for the two-color system is achieved through intercomparison of the criterion values. Numerical examples are also given to illustrate this point. The theoretical analysis not only provides an effective way of evaluating different measurement approaches, but also may help us to better understand the influences that determine the choices between wavelength/waveband measurements and calibration/noncalibration modes for temperature and soot distribution.
- OSTI ID:
- 21175738
- Journal Information:
- Applied Optics, Vol. 47, Issue 32; Other Information: DOI: 10.1364/AO.47.006112; (c) 2008 Optical Society of America; Country of input: International Atomic Energy Agency (IAEA); ISSN 0003-6935
- Country of Publication:
- United States
- Language:
- English
Similar Records
Improvements to the three-color optical CCD-based pyrometer system
Gradient effects on two-color soot optical pyrometry in a heavy-duty DI diesel engine