skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Dose Coverage Beyond the Gross Tumor Volume for Various Stereotactic Body Radiotherapy Planning Techniques Reporting Similar Control Rates for Stage I Non-Small-Cell Lung Cancer

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1];  [2];  [1]
  1. Department of Medical Physics, University of Wisconsin, Madison, WI (United States)
  2. Department of Human Oncology, University of Wisconsin, Madison, WI (United States)

Purpose: To investigate the dose falloff region for various stereotactic body radiotherapy (SBRT) planning techniques used in the treatment of Stage I non-small-cell lung cancer reporting similar control rates. Methods and Materials: The SBRT plans were constructed on five patient data sets using seven different planning regimens. These regimens varied in the number of beams, number of fractions, prescription target, and prescribed dose used. For each case all regimens were planned using a common gross tumor volume (GTV). To compare dose falloff for the various regimens, resulting physical dose grids were converted into normalized total dose (NTD) grids. Furthermore, to determine the potential coverage of microscopic extension of the various regimens minimal peripheral NTD (NTD-MP{sub 100}) were calculated and plotted as a function of incremental volume expansions of the GTV. Results: Average values for NTD-MP{sub 100} varied over a range of 174 Gy at the GTV periphery, but this range fell to 10 Gy at a distance of 14 mm from the GTV. Of 35 plans, 23 resulted in potential microscopic extension coverage of 78% to 95%. Averages for five of seven regimens fell within the range of 80% to 85%. Results were negligibly affected when intrafraction motion effects were accounted for. Conclusions: Although average NTD-MP{sub 100} varied dramatically at the GTV, periphery values became similar at a distance of 14 mm from the GTV. With the exception of two, potential coverage of microscopic extension was similar for all planning techniques, with averages falling within a 5% range.

OSTI ID:
21172525
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 72, Issue 5; Other Information: DOI: 10.1016/j.ijrobp.2008.07.048; PII: S0360-3016(08)03280-X; Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

Clinicopathologic Analysis of Microscopic Extension in Lung Adenocarcinoma: Defining Clinical Target Volume for Radiotherapy
Journal Article · Mon Oct 01 00:00:00 EDT 2007 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21172525

A phase I/II trial of stereotactic body radiation therapy (SBRT) for lung metastases: Initial report of dose escalation and early toxicity
Journal Article · Wed Nov 15 00:00:00 EST 2006 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21172525

Simulated real time image guided intrafraction tracking-delivery for hypofractionated prostate IMRT
Journal Article · Mon Sep 15 00:00:00 EDT 2008 · Medical Physics · OSTI ID:21172525