skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Steel Plate Shear Walls: Efficient Structural Solution for Slender High-Rise in China

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.2963868· OSTI ID:21149011
;  [1];  [1];  [1]
  1. Skidmore, Owings and Merrill LLP, One Front Street, San Francisco, CA 94111 (United States)

The 329.6 meter tall 74-story Jinta Tower in Tianjin, China, is expected, when complete, to be the tallest building in the world with slender steel plate shear walls used as the primary lateral load resisting system. The tower has an overall aspect ratio close to 1:8, and the main design challenge was to develop an efficient lateral system capable of resisting significant wind and seismic lateral loads, while simultaneously keeping wind induced oscillations under acceptable perception limits. This paper describes the process of selection of steel plate shear walls as the structural system, and presents the design philosophy, criteria and procedures that were arrived at by integrating the relevant requirements and recommendations of US and Chinese codes and standards, and current on-going research.

OSTI ID:
21149011
Journal Information:
AIP Conference Proceedings, Vol. 1020, Issue 1; Conference: 2008 seismic engineering conference: Commemorating the 1908 Messina and Reggio Calabria earthquake, Reggio Calabria (Italy), 8-11 Jul 2008; Other Information: DOI: 10.1063/1.2963868; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Steel shear walls, behavior, modeling and design
Journal Article · Tue Jul 08 00:00:00 EDT 2008 · AIP Conference Proceedings · OSTI ID:21149011

Cost-Benefit Analysis of High-Strength Materials for Safety-Related Nuclear Reinforced Concrete Shear Walls
Journal Article · Fri Jul 01 00:00:00 EDT 2016 · Transactions of the American Nuclear Society · OSTI ID:21149011

A More Realistic Lateral Load Pattern for Design of Reinforced Concrete Buildings with Moment Frames and Shear Walls
Journal Article · Tue Jul 08 00:00:00 EDT 2008 · AIP Conference Proceedings · OSTI ID:21149011