skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Magnitude of Residual Internal Anatomy Motion on Heavy Charged Particle Dose Distribution in Respiratory Gated Lung Therapy

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1];  [2];  [3];  [1];  [3];  [4]
  1. Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan)
  2. Accelerator Engineering Corporation, Chiba (Japan)
  3. Hospital, National Institute of Radiological Sciences, Chiba (Japan)
  4. Department of Planning and Management, National Institute of Radiological Sciences, Chiba, Japan, Chiba (Japan)

Purpose: To assess the variation in carbon beam dose distribution due to residual motion in lung cancer patients undergoing respiratory-gated radiotherapy. Methods and Materials: A total of 11 lung cancer patients underwent four-dimensional computed tomography with a 256-multislice computed tomography scanner under free-breathing conditions. A compensating bolus was designed to cover the treatment beam for all planning target volumes during a 30% duty cycle centered on exhalation (gating window). This bolus was applied to the four-dimensional computed tomography data for one respiratory cycle, and then the carbon beam dose distribution was calculated. Results: A water equivalent pathlength variation of <5 mm was observed in the gating window, but this increased to {<=}20 mm on inhalation. As a result, beam overshoot/undershoot occurred around inhalation, which increased the excessive dosing to normal tissues and the organs at risk. The dose for >95% volume irradiation is dependent on the respiratory phase but not the gating window. However, the dose for >95% volume irradiation correlated well with the tumor displacement distance. More than 90% of the dose for >95% volume irradiation could be delivered in the gating window with <4-mm tumor displacement resulting from exhalation. Conclusion: The results of our study have shown that even when the treatment beam delivery occurs outside the gating window, the prescribed dose to the target is not affected in patients with a tumor displacement of <4 mm. Thus, respiratory gating is not required in radiotherapy for patients with <4-mm tumor displacement in a respiratory cycle.

OSTI ID:
21124293
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 71, Issue 2; Other Information: DOI: 10.1016/j.ijrobp.2008.02.024; PII: S0360-3016(08)00326-X; Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

Quantitative Assessment of Range Fluctuations in Charged Particle Lung Irradiation
Journal Article · Tue Jan 01 00:00:00 EST 2008 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21124293

Impact of Real-Time Image Gating on Spot Scanning Proton Therapy for Lung Tumors: A Simulation Study
Journal Article · Sun Jan 01 00:00:00 EST 2017 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21124293

Four-Dimensional Measurement of the Displacement of Internal Fiducial Markers During 320-Multislice Computed Tomography Scanning of Thoracic Esophageal Cancer
Journal Article · Tue Feb 01 00:00:00 EST 2011 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21124293