skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Absolute calibration of photostimulable image plate detectors used as (0.5-20 MeV) high-energy proton detectors

Abstract

In this paper, the absolute calibration of photostimulable image plates (IPs) used as proton detectors is presented. The calibration is performed in a wide range of proton energies (0.5-20 MeV) by exposing simultaneously the IP and calibrated detectors (radiochromic films and solid state detector CR39) to a source of broadband laser-accelerated protons, which are spectrally resolved. The final result is a calibration curve that enables retrieving the proton number from the IP signal.

Authors:
; ; ;  [1];  [2]
  1. LULI, Ecole Polytechnique, UMR 7605, CNRS, CEA, UPMC, Route de Saclay, 91128 Palaiseau Cedex (France)
  2. Physics Department, MS 220, University of Nevada, Reno, Nevada 89557 (United States)
Publication Date:
OSTI Identifier:
21124033
Resource Type:
Journal Article
Journal Name:
Review of Scientific Instruments
Additional Journal Information:
Journal Volume: 79; Journal Issue: 7; Other Information: DOI: 10.1063/1.2949388; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); Journal ID: ISSN 0034-6748
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; BEAMS; CALIBRATION; DIAGRAMS; DIELECTRIC TRACK DETECTORS; FILMS; IMAGES; LASERS; MEV RANGE; PLATES; PROTON DETECTION; PROTONS; SENSORS; SIGNALS; SOLIDS

Citation Formats

Mancic, A, Fuchs, J, Antici, P, Audebert, P, and Gaillard, S A. Absolute calibration of photostimulable image plate detectors used as (0.5-20 MeV) high-energy proton detectors. United States: N. p., 2008. Web. doi:10.1063/1.2949388.
Mancic, A, Fuchs, J, Antici, P, Audebert, P, & Gaillard, S A. Absolute calibration of photostimulable image plate detectors used as (0.5-20 MeV) high-energy proton detectors. United States. https://doi.org/10.1063/1.2949388
Mancic, A, Fuchs, J, Antici, P, Audebert, P, and Gaillard, S A. 2008. "Absolute calibration of photostimulable image plate detectors used as (0.5-20 MeV) high-energy proton detectors". United States. https://doi.org/10.1063/1.2949388.
@article{osti_21124033,
title = {Absolute calibration of photostimulable image plate detectors used as (0.5-20 MeV) high-energy proton detectors},
author = {Mancic, A and Fuchs, J and Antici, P and Audebert, P and Gaillard, S A},
abstractNote = {In this paper, the absolute calibration of photostimulable image plates (IPs) used as proton detectors is presented. The calibration is performed in a wide range of proton energies (0.5-20 MeV) by exposing simultaneously the IP and calibrated detectors (radiochromic films and solid state detector CR39) to a source of broadband laser-accelerated protons, which are spectrally resolved. The final result is a calibration curve that enables retrieving the proton number from the IP signal.},
doi = {10.1063/1.2949388},
url = {https://www.osti.gov/biblio/21124033}, journal = {Review of Scientific Instruments},
issn = {0034-6748},
number = 7,
volume = 79,
place = {United States},
year = {Tue Jul 15 00:00:00 EDT 2008},
month = {Tue Jul 15 00:00:00 EDT 2008}
}