skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Percutaneous Transcatheter One-Step Mechanical Aortic Disc Valve Prosthesis Implantation: A Preliminary Feasibility Study in Swine

Journal Article · · Cardiovascular and Interventional Radiology
 [1]; ;  [2]; ; ;  [3]
  1. Institute for Clinical and Experimental Medicine, Intensive Care Unit, Clinic of Cardiology (Czech Republic)
  2. Institute for Clinical and Experimental Medicine, Department of Diagnostic and Interventional Radiology (Czech Republic)
  3. Oregon Health and Sciences University, Dotter Interventional Institute (United States)

Purpose. To evaluate the feasibility of one-step implantation of a new type of stent-based mechanical aortic disc valve prosthesis (MADVP) above and across the native aortic valve and its short-term function in swine with both functional and dysfunctional native valves. Methods. The MADVP consisted of a folding disc valve made of silicone elastomer attached to either a nitinol Z-stent (Z model) or a nitinol cross-braided stent (SX model). Implantation of 10 MADVPs (6 Z and 4 SX models) was attempted in 10 swine: 4 (2 Z and 2 SX models) with a functional native valve and 6 (4 Z and 2 SX models) with aortic regurgitation induced either by intentional valve injury or by MADVP placement across the native valve. MADVP function was observed for up to 3 hr after implantation. Results. MADVP implantation was successful in 9 swine. One animal died of induced massive regurgitation prior to implantation. Four MADVPs implanted above functioning native valves exhibited good function. In 5 swine with regurgitation, MADVP implantation corrected the induced native valve dysfunction and the device's continuous good function was observed in 4 animals. One MADVP (SX model) placed across native valve gradually migrated into the left ventricle. Conclusion. The tested MADVP can be implanted above and across the native valve in a one-step procedure and can replace the function of the regurgitating native valve. Further technical development and testing are warranted, preferably with a manufactured MADVP.

OSTI ID:
21091276
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 29, Issue 1; Other Information: DOI: 10.1007/s00270-005-0029-9; Copyright (c) 2006 Springer Science+Business Media, Inc.; www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English