Percutaneous Transcatheter One-Step Mechanical Aortic Disc Valve Prosthesis Implantation: A Preliminary Feasibility Study in Swine
- Institute for Clinical and Experimental Medicine, Intensive Care Unit, Clinic of Cardiology (Czech Republic)
- Institute for Clinical and Experimental Medicine, Department of Diagnostic and Interventional Radiology (Czech Republic)
- Oregon Health and Sciences University, Dotter Interventional Institute (United States)
Purpose. To evaluate the feasibility of one-step implantation of a new type of stent-based mechanical aortic disc valve prosthesis (MADVP) above and across the native aortic valve and its short-term function in swine with both functional and dysfunctional native valves. Methods. The MADVP consisted of a folding disc valve made of silicone elastomer attached to either a nitinol Z-stent (Z model) or a nitinol cross-braided stent (SX model). Implantation of 10 MADVPs (6 Z and 4 SX models) was attempted in 10 swine: 4 (2 Z and 2 SX models) with a functional native valve and 6 (4 Z and 2 SX models) with aortic regurgitation induced either by intentional valve injury or by MADVP placement across the native valve. MADVP function was observed for up to 3 hr after implantation. Results. MADVP implantation was successful in 9 swine. One animal died of induced massive regurgitation prior to implantation. Four MADVPs implanted above functioning native valves exhibited good function. In 5 swine with regurgitation, MADVP implantation corrected the induced native valve dysfunction and the device's continuous good function was observed in 4 animals. One MADVP (SX model) placed across native valve gradually migrated into the left ventricle. Conclusion. The tested MADVP can be implanted above and across the native valve in a one-step procedure and can replace the function of the regurgitating native valve. Further technical development and testing are warranted, preferably with a manufactured MADVP.
- OSTI ID:
- 21091276
- Journal Information:
- Cardiovascular and Interventional Radiology, Vol. 29, Issue 1; Other Information: DOI: 10.1007/s00270-005-0029-9; Copyright (c) 2006 Springer Science+Business Media, Inc.; www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
- Country of Publication:
- United States
- Language:
- English
Similar Records
Percutaneous Transcatheter Aortic Disc Valve Prosthesis Implantation: A Feasibility Study
First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept