Title: Resolved Abdominal Aortic Aneurysms Following Stent Graft Treatment: A Report of Five Cases

Abstract

Complete aneurysm resolution is the hallmark of successful endoluminal stent-graft treatment. We describe 5 patients in whom an abdominal aortic aneurysm (AAA) disappeared completely at mid-term follow-up after endovascular stent-graft placement. We reviewed 45 patients (43 men and 2 women) who underwent AAA repair using an endovascular technique, from April 1997 to December 2001. Mean AAA diameter was 58.3 mm. On 48-month follow-up, 12 aneurysms had not changed in size, 4 had grown, 16 had shrunk, and 5 had resolved completely. We describe these 5 patients in detail. The 5 patients were all men, mean age 68 years; their mean aneurysmal sac diameter was 54 mm. The only common finding in all of them was patency of lumbar and inferior mesenteric arteries at pre-procedure evaluation as well as at follow-up. Mean time to complete resolution was 18 months. No major complications were encountered. AAA may resolve completely after endovascular stent-graft implantation. Patent side branches may perhaps contribute to AAA disappearance by antegrade flow. A larger patient population should be reviewed, however, before any statistical conclusion can be drawn.

Authors:
; ; ;  [1]; ;  [2];  [1]
  1. Chaim Sheba Medical Center, affiliated with Tel-Aviv University Sackler School of Medicine, Tel-Aviv Tel-Hashomer 52621, Departments of Diagnostic Radiology (Israel)
  2. Chaim Sheba Medical Center, affiliated with Tel-Aviv University Sackler School of Medicine, Tel-Aviv Tel-Hashomer 52621, Vascular Surgery (Israel)
Publication Date:
OSTI Identifier:
21088299
Resource Type:
Journal Article
Resource Relation:
Journal Name: Cardiovascular and Interventional Radiology; Journal Volume: 27; Journal Issue: 2; Other Information: DOI: 10.1007/s00270-003-2708-8; Copyright (c) 2004 Springer-Verlag; Article Copyright (c) 2004 Springer-Verlag New York, Inc.; www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; ARTERIES; EVALUATION; GRAFTS; PATENTS; PATIENTS; VASCULAR DISEASES

Citation Formats

Rimon, Uri, Garniek, Alexander, Golan, Gil, Bensaid, Paul, Galili, Yair, Schneiderman, Jacob, and Morag, Benyamina. Resolved Abdominal Aortic Aneurysms Following Stent Graft Treatment: A Report of Five Cases. United States: N. p., 2004. Web. doi:10.1007/S00270-003-2708-8.
Rimon, Uri, Garniek, Alexander, Golan, Gil, Bensaid, Paul, Galili, Yair, Schneiderman, Jacob, & Morag, Benyamina. Resolved Abdominal Aortic Aneurysms Following Stent Graft Treatment: A Report of Five Cases. United States. doi:10.1007/S00270-003-2708-8.
Rimon, Uri, Garniek, Alexander, Golan, Gil, Bensaid, Paul, Galili, Yair, Schneiderman, Jacob, and Morag, Benyamina. 2004. "Resolved Abdominal Aortic Aneurysms Following Stent Graft Treatment: A Report of Five Cases". United States. doi:10.1007/S00270-003-2708-8.
@article{osti_21088299,
title = {Resolved Abdominal Aortic Aneurysms Following Stent Graft Treatment: A Report of Five Cases},
author = {Rimon, Uri and Garniek, Alexander and Golan, Gil and Bensaid, Paul and Galili, Yair and Schneiderman, Jacob and Morag, Benyamina},
abstractNote = {Complete aneurysm resolution is the hallmark of successful endoluminal stent-graft treatment. We describe 5 patients in whom an abdominal aortic aneurysm (AAA) disappeared completely at mid-term follow-up after endovascular stent-graft placement. We reviewed 45 patients (43 men and 2 women) who underwent AAA repair using an endovascular technique, from April 1997 to December 2001. Mean AAA diameter was 58.3 mm. On 48-month follow-up, 12 aneurysms had not changed in size, 4 had grown, 16 had shrunk, and 5 had resolved completely. We describe these 5 patients in detail. The 5 patients were all men, mean age 68 years; their mean aneurysmal sac diameter was 54 mm. The only common finding in all of them was patency of lumbar and inferior mesenteric arteries at pre-procedure evaluation as well as at follow-up. Mean time to complete resolution was 18 months. No major complications were encountered. AAA may resolve completely after endovascular stent-graft implantation. Patent side branches may perhaps contribute to AAA disappearance by antegrade flow. A larger patient population should be reviewed, however, before any statistical conclusion can be drawn.},
doi = {10.1007/S00270-003-2708-8},
journal = {Cardiovascular and Interventional Radiology},
number = 2,
volume = 27,
place = {United States},
year = 2004,
month = 3
}
  • Objective. To evaluate the mid-term feasibility, efficacy, and durability of descending thoracic aortic aneurysm (DTAA) exclusion using the EndoFit device (LeMaitre Vascular). Methods. Twenty-three (23) men (mean age 66 years) with a DTAA were admitted to our department for endovascular repair (21 were ASA III+ and 2 refused open repair) from January 2003 to July 2005. Results. Complete aneurysm exclusion was feasible in all subjects (100% technical success). The median follow-up was 18 months (range 8-40 months). A single stent-graft was used in 6 cases. The deployment of a second stent-graft was required in the remaining 17 patients. All endograftsmore » were attached proximally, beyond the left subclavian artery, leaving the aortic arch branches intact. No procedure-related deaths have occurred. A distal type I endoleak was detected in 2 cases on the 1 month follow-up CT scan, and was repaired with reintervention and deployment of an extension graft. A nonfatal acute myocardial infarction occurred in 1 patient in the sixth postoperative month. Graft migration, graft infection, paraplegia, cerebral or distal embolization, renal impairment or any other major complications were not observed. Conclusion. The treatment of DTAAs using the EndoFit stent-graft is technically feasible. Mid-term results in this series are promising.« less
  • Purpose: This study was designed to assess the long-term outcome of selected patients with aortic, aortoiliac, and isolated common iliac aneurysms treated with the GORE EXCLUDER{sup Registered-Sign} stent-graft. Methods: Between December 1998 and June 2010, 121 nonconsecutive patients underwent insertion of a GORE EXCLUDER{sup Registered-Sign} stent-graft to treat an aortic (n = 80; 66%), aortoiliac (n = 25; 21%), or isolated common iliac (n = 16; 13%) aneurysm. Procedural and follow-up data were collected prospectively. Primary endpoints are overall survival, intervention-free survival, and freedom from aneurysm rupture. Secondary endpoints are device- and procedure-related complications, including all types of endoleaks ormore » endotension, and reintervention. Results: The mean follow-up is 4.98 years (standard deviation, 3.18; median follow-up, 4.05 years). The estimated percentage overall survival (with 95% confidence interval) after respectively 5 and 10 years of follow-up is 74.5% (65.8; 81.3) and 57.8% (47.7; 66.7). The estimated intervention-free survival after respectively 5 and 10 years is 90% (84.3; 96.1) and 77.7% (67; 88.4). There was no aneurysm rupture during follow-up. Early postoperative complications occurred in 16 patients (13%); none were fatal. Late reinterventions were performed in 18 patients (15%). Finally, throughout the follow-up period, endoleaks were identified: type I (n = 4; 3%); type II (n = 39; 32%); type III (n = 0; 0%); endotension was seen in 11 patients (9%). Conclusions: Aneurysm exclusion with use of the GORE EXCLUDER{sup Registered-Sign} stent-graft is durable through a mean follow-up of nearly 5 years. There was no postprocedural aneurysm rupture. Complications occurred throughout the follow-up period, requiring continued clinical and radiological surveillance.« less
  • The purpose of this study was to evaluate the usefulness of a bifurcated stent-graft with a wide iliac limb end (WILE) in the treatment of abdominal aortic aneurysm (AAA) with a dilated common iliac artery (CIA) to avoid occlusion of the internaliliac artery (IIA). The WILE, covered with an expanded polytetrafluoroethylene graft which was constructed of large diameter stents according to the individual CIA diameter, was connected to a two-piece bifurcated stent-graft covering a polyester graft. The WILE was placed in eight dilated CIAs of six patients. All but one WILE fitted the dilated CIA well. One did not fit,more » and coil embolization of the leak was needed. All eight IIA derived from the dilated CIA avoided occlusion. Perigraft leak due to other causes was identified in another two patients. Limb kinking was observed in two patients. Our stent is useful in the treatment of AAA with dilated CIA to avoid occlusion of the IIA, and may extend the indication of endoluminal repair of AAA.« less
  • The purpose of the study was to investigate the hemodynamic effect of stent struts (wires) on renal arteries in patients with abdominal aortic aneurysms (AAAs) treated with suprarenal stent-grafts. Two sample patients with AAA undergoing multislice CT angiography pre- and postsuprarenal fixation of stent-grafts were selected for inclusion in the study. Eight juxtarenal models focusing on the renal arteries were generated from the multislice CT datasets. Four types of configurations of stent wires crossing the renal artery ostium were simulated in the segmented aorta models: a single wire crossing centrally, a single wire crossing peripherally, a V-shaped wire crossing centrally,more » and multiple wires crossing peripherally. The blood flow pattern, flow velocity, wall pressure, and wall shear stress at the renal arteries pre- and post-stent-grafting were analyzed and compared using a two-way fluid structure interaction analysis. The stent wire thickness was simulated with a diameter of 0.4, 1.0, and 2.0 mm, and hemodynamic analysis was performed at different cardiac cycles. The interference of stent wires with renal blood flow was mainly determined by the thickness of stent wires and the type of configuration of stent wires crossing the renal ostium. The flow velocity was reduced by 20-30% in most of the situations when the stent wire thickness increased to 1.0 and 2.0 mm. Of the four types of configuration, the single wire crossing centrally resulted in the highest reduction of flow velocity, ranging from 21% to 28.9% among three different wire thicknesses. Wall shear stress was also dependent on the wire thickness, which decreased significantly when the wire thickness reached 1.0 and 2.0 mm. In conclusion, our preliminary study showed that the hemodynamic effect of suprarenal stent wires in patients with AAA treated with suprarenal stent-grafts was determined by the thickness of suprarenal stent wires. Research findings in our study are useful for follow-up of patients treated with suprarenal stent-grafts to ensure long-term safety of the suprarenal fixation.« less
  • The endovascular repair of abdominal aorticaneurysm (AAA) with stent grafts is rapidly becoming an important alternative to open repair. Suprarenal stent grafting, recently modified from conventional infrarenal stent grafting, is a technique for the purpose of treating patients with inappropriate aneurysm necks.Unlike open repair, the success of endoluminal repair cannot be ascertained by means of direct examination and thus relies on imaging results. The use of conventional angiography for arterial imaging has become less dominant, while helical computed tomography angiography(CTA) has become the imaging modality of choice for both preoperative assessment and postoperative followup after treatment with stent graft implants.more » There is an increasing likelihood that radiologists will become more and more involved in the procedure of aortic stent grafting and in giving the radiological report on these patients treated with stent grafts. It is necessary for radiologists to be familiar with the imaging findings, including common and uncommon appearances following aortic stent grafting. The purpose of this pictorial essay is to describe and present normal and abnormal imaging appearances following aortic stent grafting based on helical CTA.« less