Title: Resonant excitation of injected atomic ions in an ion trap mass spectrometer

Abstract

Resonant excitation of ion motion in an ion trap mass spectrometer(ITMS) is not a new idea. Most previous reports have characterized the resonant absorption profile (loss of observed ion signal versus excitation frequency) with respect to space charge, and the amplitude (V{sub ac}) and duration (T) of the excitation pulse. These reports have often focused on (single frequency) resonant excitation to effect collisionally induced dissociation for MS/MS. The authors report studies of single frequency and broadband resonant excitation applied to selective ion accumulation or ejection in elemental mass spectrometry.

Authors:
; ;  [1]
  1. Pacific Northwest Lab., Richland, WA (United States); and others
Publication Date:
OSTI Identifier:
210694
Report Number(s):
CONF-9505261-
TRN: 96:001157-0133
Resource Type:
Conference
Resource Relation:
Conference: 43. American Society of Mass Spectrometry (ASMS) conference on mass spectrometry and allied topics, Atlanta, GA (United States), 21-26 May 1995; Other Information: PBD: 1995; Related Information: Is Part Of Proceedings of the 43rd ASMS conference on mass spectrometry and allied topics; PB: 1411 p.
Country of Publication:
United States
Language:
English
Subject:
40 CHEMISTRY; SILVER; ICP MASS SPECTROSCOPY; CADMIUM; STRONTIUM; YTTRIUM; ZIRCONIUM

Citation Formats

Eiden, G C, Barinaga, C J, and Koppenaal, D W. Resonant excitation of injected atomic ions in an ion trap mass spectrometer. United States: N. p., 1995. Web.
Eiden, G C, Barinaga, C J, & Koppenaal, D W. Resonant excitation of injected atomic ions in an ion trap mass spectrometer. United States.
Eiden, G C, Barinaga, C J, and Koppenaal, D W. Sun . "Resonant excitation of injected atomic ions in an ion trap mass spectrometer". United States.
@article{osti_210694,
title = {Resonant excitation of injected atomic ions in an ion trap mass spectrometer},
author = {Eiden, G C and Barinaga, C J and Koppenaal, D W},
abstractNote = {Resonant excitation of ion motion in an ion trap mass spectrometer(ITMS) is not a new idea. Most previous reports have characterized the resonant absorption profile (loss of observed ion signal versus excitation frequency) with respect to space charge, and the amplitude (V{sub ac}) and duration (T) of the excitation pulse. These reports have often focused on (single frequency) resonant excitation to effect collisionally induced dissociation for MS/MS. The authors report studies of single frequency and broadband resonant excitation applied to selective ion accumulation or ejection in elemental mass spectrometry.},
doi = {},
url = {https://www.osti.gov/biblio/210694}, journal = {},
number = ,
volume = ,
place = {United States},
year = {1995},
month = {12}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: