skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Status and Highlights of CANDLE Synchrotron Light Source Project in Armenia

Abstract

CANDLE - Center for the Advancement of Natural Discoveries using Light Emission - is a 3 GeV energy synchrotron light facility project in the Republic of Armenia. The facility has the potential to provide more than 40 beamlines from bends, undulators and wigglers in wide spectral range from ultraviolet to hard X-Rays. The project is supposed to be an international facility for advanced studies in life and material sciences. The main features and the status of the project are presented. The preliminary list of first group beamlines is discussed.

Authors:
 [1]
  1. Center for the Advancement of Natural Discoveries using Light Emission, Acharyan 31, 375040, Yerevan (Armenia)
Publication Date:
OSTI Identifier:
21043415
Resource Type:
Journal Article
Resource Relation:
Journal Name: AIP Conference Proceedings; Journal Volume: 879; Journal Issue: 1; Conference: 9. international conference on synchrotron radiation instrumentation, Daegu (Korea, Republic of), 28 May - 2 Jun 2006; Other Information: DOI: 10.1063/1.2436040; (c) 2007 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; ARMENIA; BEAM PRODUCTION; GEV RANGE; HARD X RADIATION; LIGHT SOURCES; PHOTON BEAMS; PHOTON EMISSION; SYNCHROTRON RADIATION; ULTRAVIOLET RADIATION; WIGGLER MAGNETS

Citation Formats

Tsakanov, V. M.. Status and Highlights of CANDLE Synchrotron Light Source Project in Armenia. United States: N. p., 2007. Web. doi:10.1063/1.2436040.
Tsakanov, V. M.. Status and Highlights of CANDLE Synchrotron Light Source Project in Armenia. United States. doi:10.1063/1.2436040.
Tsakanov, V. M.. Fri . "Status and Highlights of CANDLE Synchrotron Light Source Project in Armenia". United States. doi:10.1063/1.2436040.
@article{osti_21043415,
title = {Status and Highlights of CANDLE Synchrotron Light Source Project in Armenia},
author = {Tsakanov, V. M.},
abstractNote = {CANDLE - Center for the Advancement of Natural Discoveries using Light Emission - is a 3 GeV energy synchrotron light facility project in the Republic of Armenia. The facility has the potential to provide more than 40 beamlines from bends, undulators and wigglers in wide spectral range from ultraviolet to hard X-Rays. The project is supposed to be an international facility for advanced studies in life and material sciences. The main features and the status of the project are presented. The preliminary list of first group beamlines is discussed.},
doi = {10.1063/1.2436040},
journal = {AIP Conference Proceedings},
number = 1,
volume = 879,
place = {United States},
year = {Fri Jan 19 00:00:00 EST 2007},
month = {Fri Jan 19 00:00:00 EST 2007}
}
  • The construction program of AURORA, the compact synchrotron light source, was started in the fall of 1986, and is now at the final assembly stage. We have observed a good uniform field from the superconducting magnet. In this article the construction status of the superconducting electron storage ring, injection microtron, beam monitoring, and control system is briefly reported.
  • The Dortmund Electron Accelerator DELTA, located at the University of Dortmund, changed its scope during the last years into a 1.5 GeV synchrotron light source. DELTA is now operated for 3000 h per year including 2000 h dedicated beam time for synchrotron radiation use and 1000 h for machine physics, optimization and maintenance. The status of the accelerator complex is presented together with the beam operation, the installation and commissioning of beamlines and insertion devices. To serve user demands of photon energies up to more than 10 keV a 5.3 T superconducting asymmetric multipole wiggler (SAW) with a critical energymore » of 7.9 keV has been installed serving three beamlines in the hard X-ray regime with also circular polarization. Two undulator beamlines for photon energies between 5 and 400 eV (U250) and between 55 and 1500 eV (U55) and several dipole beamlines up to 200 eV are under operation. The construction and operation of the different beamlines is done by various universities and laboratories in Nordrhein-Westfalen.« less
  • The Dortmund Electron Accelerator DELTA, a 1.5 GeV synchrotron light source located at University of Dortmund, is operated for 3000 h per year including 2000 h beam time for synchrotron radiation use and 1000 h for machine physics, optimisation and maintenance. The status of the synchrotron light source is presented with emphasis on the operation, commissioning and installation of beamlines and insertion devices. The soft X-ray undulator beamlines provide photon energies between 5 to 400 eV (U250) and 55 and 1500 eV (U55), respectively. One dipole beamline covers soft X-rays between 6 to 200 eV, and a second dipole beamlinemore » is used without a monochromator at 2.2 keV critical energy of the dipole spectrum. For photons in the hard X-ray regime, a superconducting asymmetric wiggler (SAW) with a field of 5.3 T and 7.9 keV critical energy was installed, providing circularly polarized X-rays in the range of 2 to 30 keV. Due to its broad radiation fan, three beamlines are simultaneously served. The first SAW-beamline with an energy range between 4 to 30 keV is in full operation, the second is under commissioning, serving the energy range between 2 to 30 keV. The third SAW beamline is near completion, additional dipole beamlines are under construction.« less
  • Two high intensity storage rings are being constructed at Brookhaven National Laboratory for the generation of intense fluxes of synchrotron radiation in the vuv wavelength region (700 MeV ring, lambda/sub c/ = 31.5 A) and in the x-ray wavelength region (2.5 GeV ring, lambda/sub c/ = 2.5 A). A description is given of the facility, the main features of the storage rings are presented and the basic parameters are enumerated. High field superconducting wigglers, to lower the short wavelength cutoff in the x-ray ring, and undulators, for flux enhancement or a free electron laser experiment will be incorporated and parametersmore » are given here. Special design aspects to optimize the electron storage rings as dedicated synchrotron radiation sources will be emphasized and the status of the project will be given.« less
  • The National Synchrotron Light Source (NSLS) ceased operation in September 2014 and was succeeded by NSLS-II. There were four in-vacuum undulators (IVUs) in operation at NSLS. The most recently constructed IVU for NSLS was the mini-gap undulator (MGU-X25, to be renamed IVU18 for NSLS-II), which was constructed in 2006. This device was selected to be reused for the New York Structural Biology Consortium Microdiffraction beamline at NSLS-II. At the time of construction, IVU18 was a state-of-the-art undulator designed to be operated as a cryogenic permanent-magnet undulator. Due to the more stringent field quality and impedance requirements of the NSLS-II ring,more » the transition region was redesigned. The control system was also updated to NSLS-II specifications. As a result, this paper reports the details of the IVU18 refurbishment activities including additional magnetic measurement and tuning.« less