New Measurement of the Electron Magnetic Moment Using a One-Electron Quantum Cyclotron
Journal Article
·
· Physical Review Letters
- Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States)
A new measurement resolves cyclotron and spin levels for a single-electron quantum cyclotron to obtain an electron magnetic moment, given by g/2=1.001 159 652 180 85 (76) [0.76 ppt]. The uncertainty is nearly 6 times lower than in the past, and g is shifted downward by 1.7 standard deviations. The new g, with a quantum electrodynamics (QED) calculation, determines the fine structure constant with a 0.7 ppb uncertainty--10 times smaller than for atom-recoil determinations. Remarkably, this 100 mK measurement probes for internal electron structure at 130 GeV.
- OSTI ID:
- 20860524
- Journal Information:
- Physical Review Letters, Vol. 97, Issue 3; Other Information: DOI: 10.1103/PhysRevLett.97.030801; (c) 2006 The American Physical Society; Country of input: International Atomic Energy Agency (IAEA); ISSN 0031-9007
- Country of Publication:
- United States
- Language:
- English
Similar Records
New Measurement of the Electron Magnetic Moment and the Fine Structure Constant
New Measurement of the Electron Magnetic Moment and the Fine Structure Constant
Cavity control of a single-electron quantum cyclotron: Measuring the electron magnetic moment
Journal Article
·
Fri Mar 28 00:00:00 EDT 2008
· Physical Review Letters
·
OSTI ID:20860524
New Measurement of the Electron Magnetic Moment and the Fine Structure Constant
Journal Article
·
Fri Nov 17 00:00:00 EST 2006
· AIP Conference Proceedings
·
OSTI ID:20860524
Cavity control of a single-electron quantum cyclotron: Measuring the electron magnetic moment
Journal Article
·
Sun May 15 00:00:00 EDT 2011
· Physical Review. A
·
OSTI ID:20860524