Title: Ambient illumination revisited: A new adaptation-based approach for optimizing medical imaging reading environments

Abstract

Ambient lighting in soft-copy reading rooms is currently kept at low values to preserve contrast rendition in the dark regions of a medical image. Low illuminance levels, however, create inadequate viewing conditions and may also cause eye strain. This eye strain may be potentially attributed to notable variations in the luminance adaptation state of the reader's eyes when moving the gaze intermittently between the brighter display and darker surrounding surfaces. This paper presents a methodology to minimize this variation and optimize the lighting conditions of reading rooms by exploiting the properties of liquid crystal displays (LCDs) with low diffuse reflection coefficients and high luminance ratio. First, a computational model was developed to determine a global luminance adaptation value, L{sub adp}, when viewing a medical image on display. The model is based on the diameter of the pupil size, which depends on the luminance of the observed object. Second, this value was compared with the luminance reflected off surrounding surfaces, L{sub s}, under various conditions of room illuminance, E, different values of diffuse reflection coefficients of surrounding surfaces, R{sub s}, and calibration settings of a typical LCD. The results suggest that for typical luminance settings of current LCDs, it is possiblemore » to raise ambient illumination to minimize differences in eye adaptation, potentially reducing visual fatigue while also complying with the TG18 specifications for controlled contrast rendition. Specifically, room illumination in the 75-150 lux range and surface diffuse reflection coefficients in the practical range of 0.13-0.22 sr{sup -1} provide an ideal setup for typical LCDs. Future LCDs with lower diffuse reflectivity and with higher inherent luminance ratios can provide further improvement of ergonomic viewing conditions in reading rooms.« less

Authors:
;  [1];  [2]
  1. Duke Advanced Imaging Laboratories, Departments of Radiology and Biomedical Engineering, Duke University, Durham, North Carolina 27705 (United States)
  2. (United States)
Publication Date:
OSTI Identifier:
20853937
Resource Type:
Journal Article
Resource Relation:
Journal Name: Medical Physics; Journal Volume: 34; Journal Issue: 1; Other Information: DOI: 10.1118/1.2402583; (c) 2007 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; BRIGHTNESS; CALIBRATION; EYES; ILLUMINANCE; IMAGE PROCESSING; IMAGES; LIQUID CRYSTALS; REFLECTION; REFLECTIVITY

Citation Formats

Chawla, Amarpreet S., Samei, Ehsan, and Duke Advanced Imaging Laboratories, Departments of Radiology, Physics, Medical Physics, and Biomedical Engineering, Duke University, Durham, North Carolina 27705. Ambient illumination revisited: A new adaptation-based approach for optimizing medical imaging reading environments. United States: N. p., 2007. Web. doi:10.1118/1.2402583.
Chawla, Amarpreet S., Samei, Ehsan, & Duke Advanced Imaging Laboratories, Departments of Radiology, Physics, Medical Physics, and Biomedical Engineering, Duke University, Durham, North Carolina 27705. Ambient illumination revisited: A new adaptation-based approach for optimizing medical imaging reading environments. United States. doi:10.1118/1.2402583.
Chawla, Amarpreet S., Samei, Ehsan, and Duke Advanced Imaging Laboratories, Departments of Radiology, Physics, Medical Physics, and Biomedical Engineering, Duke University, Durham, North Carolina 27705. Mon . "Ambient illumination revisited: A new adaptation-based approach for optimizing medical imaging reading environments". United States. doi:10.1118/1.2402583.
@article{osti_20853937,
title = {Ambient illumination revisited: A new adaptation-based approach for optimizing medical imaging reading environments},
author = {Chawla, Amarpreet S. and Samei, Ehsan and Duke Advanced Imaging Laboratories, Departments of Radiology, Physics, Medical Physics, and Biomedical Engineering, Duke University, Durham, North Carolina 27705},
abstractNote = {Ambient lighting in soft-copy reading rooms is currently kept at low values to preserve contrast rendition in the dark regions of a medical image. Low illuminance levels, however, create inadequate viewing conditions and may also cause eye strain. This eye strain may be potentially attributed to notable variations in the luminance adaptation state of the reader's eyes when moving the gaze intermittently between the brighter display and darker surrounding surfaces. This paper presents a methodology to minimize this variation and optimize the lighting conditions of reading rooms by exploiting the properties of liquid crystal displays (LCDs) with low diffuse reflection coefficients and high luminance ratio. First, a computational model was developed to determine a global luminance adaptation value, L{sub adp}, when viewing a medical image on display. The model is based on the diameter of the pupil size, which depends on the luminance of the observed object. Second, this value was compared with the luminance reflected off surrounding surfaces, L{sub s}, under various conditions of room illuminance, E, different values of diffuse reflection coefficients of surrounding surfaces, R{sub s}, and calibration settings of a typical LCD. The results suggest that for typical luminance settings of current LCDs, it is possible to raise ambient illumination to minimize differences in eye adaptation, potentially reducing visual fatigue while also complying with the TG18 specifications for controlled contrast rendition. Specifically, room illumination in the 75-150 lux range and surface diffuse reflection coefficients in the practical range of 0.13-0.22 sr{sup -1} provide an ideal setup for typical LCDs. Future LCDs with lower diffuse reflectivity and with higher inherent luminance ratios can provide further improvement of ergonomic viewing conditions in reading rooms.},
doi = {10.1118/1.2402583},
journal = {Medical Physics},
number = 1,
volume = 34,
place = {United States},
year = {Mon Jan 15 00:00:00 EST 2007},
month = {Mon Jan 15 00:00:00 EST 2007}
}
  • Purpose: The purpose of this work was to develop and evaluate a new method for calibration of medical displays that includes the effect of fixed adaptation and by using equipment and luminance levels typical for a modern radiology department. Methods: Low contrast sinusoidal test patterns were derived at nine luminance levels from 2 to 600 cd/m{sup 2} and used in a two alternative forced choice observer study, where the adaptation level was fixed at the logarithmic average of 35 cd/m{sup 2}. The contrast sensitivity at each luminance level was derived by establishing a linear relationship between the ten pattern contrastmore » levels used at every luminance level and a detectability index (d′) calculated from the fraction of correct responses. A Gaussian function was fitted to the data and normalized to the adaptation level. The corresponding equation was used in a display calibration method that included the grayscale standard display function (GSDF) but compensated for fixed adaptation. In the evaluation study, the contrast of circular objects with a fixed pixel contrast was displayed using both calibration methods and was rated on a five-grade scale. Results were calculated using a visual grading characteristics method. Error estimations in both observer studies were derived using a bootstrap method. Results: The contrast sensitivities for the darkest and brightest patterns compared to the contrast sensitivity at the adaptation luminance were 37% and 56%, respectively. The obtained Gaussian fit corresponded well with similar studies. The evaluation study showed a higher degree of equally distributed contrast throughout the luminance range with the calibration method compensated for fixed adaptation than for the GSDF. The two lowest scores for the GSDF were obtained for the darkest and brightest patterns. These scores were significantly lower than the lowest score obtained for the compensated GSDF. For the GSDF, the scores for all luminance levels were statistically separated from the average value; three were lower and two were higher. For the compensated GSDF, three of the scores could not be separated from the average value. Conclusions: An observer study using clinically relevant displays and luminance settings has demonstrated that the calibration of displays according to the GSDF causes the perceived contrast to be unevenly distributed when using displays with a high luminance range. As the luminance range increases, the perceived contrast in the dark and bright regions will be significantly lower than the perceived contrast in the middle of the luminance range. A new calibration method that includes the effect of fixed adaptation was developed and evaluated in an observer study and was found to distribute the contrast of the display more evenly throughout the grayscale than the GSDF.« less
  • Most electronic portal imaging devices (EPIDs) developed so far use a Cu plate/phosphor screen to absorb x rays and convert their energies into light, and the light image is then read out. The main problem with this approach is that the Cu plate/phosphor screen must be thin ({approx}2 mm thick) in order to obtain a high spatial resolution, resulting in a low x-ray absorption or low quantum efficiency for megavoltage x rays (typically 2-4%). In addition, the phosphor screen contains high atomic number (high-Z) materials, resulting in an over-response of the detector to low-energy x rays in dosimetric verification. Inmore » this paper, we propose a new approach that uses Cerenkov radiation to convert x-ray energy absorbed by the detector into light for portal imaging applications. With our approach, a thick ({approx}10-30 cm) energy conversion layer made of a low-Z dielectric medium, such as a large-area, thick fiber-optic taper consisting of a matrix of optical fibers aligned with the incident x rays, is used to replace the thin Cu plate/phosphor screen. The feasibility of this approach has been investigated using a single optical fiber embedded in a solid material. The spatial resolution expressed by the modulation transfer function (MTF) and the sensitivity of the detector at low doses ({approx} one Linac pulse) have been measured. It is predicted that, using this approach, a detective quantum efficiency of an order of magnitude higher at zero frequency can be obtained while maintaining a reasonable MTF, as compared to current EPIDs.« less
  • Thermoluminescent detectors (TLDs) can provide accurate and precise measurements for both patient and personnel dosimetry in the medical imaging environment. They have the advantages of tissue equivalency, an excellent dynamic range, and dose rate independence. In the work reported here, experiments with planar x-ray, fluoroscopy, and a 57Co source were conducted to test the repeatability and energy dependence of an LiF TL ribbon/automatic reader system and a four-element CaSO2 and Li2B4O7 badge/automatic reader system for diagnostic radiology and nuclear medicine dosimetry. The results indicate the usefulness and appropriateness of the TLD systems tested for both personnel and patient dosimetry inmore » the medical diagnostic environment.« less
  • In this paper, we develop an approach to magneto optical imaging (MOI), applying a ghost imaging (GI) protocol to perform Faraday microscopy. MOI is of the utmost importance for the investigation of magnetic properties of material samples, through Weiss domains shape, dimension and dynamics analysis. Nevertheless, in some extreme conditions such as cryogenic temperatures or high magnetic field applications, there exists a lack of domain images due to the difficulty in creating an efficient imaging system in such environments. Here, we present an innovative MOI technique that separates the imaging optical path from the one illuminating the object. The techniquemore » is based on thermal light GI and exploits correlations between light beams to retrieve the image of magnetic domains. As a proof of principle, the proposed technique is applied to the Faraday magneto-optical observation of the remanence domain structure of an yttrium iron garnet sample.« less