Segmentation of lymphoma containing lymph nodes is a difficult task because of multiple variables associated with the tumor's location, intensity distribution, and contrast to its surrounding tissues. In this paper, we present a reliable and practical marker-controlled watershed algorithm for semi-automated segmentation of lymphoma in sequential CT images. Robust determination of internal and external markers is the key to successful use of the marker-controlled watershed transform in the segmentation of lymphoma and is the focus of this work. The external marker in our algorithm is the circle enclosing the lymphoma in a single slice. The internal marker, however, is determined automatically by combining techniques including Canny edge detection, thresholding, morphological operation, and distance map estimation. To obtain tumor volume, the segmented lymphoma in the current slice needs to be propagated to the adjacent slice to help determine the external and internal markers for delineation of the lymphoma in that slice. The algorithm was applied to 29 lymphomas (size range, 9-53 mm in diameter; mean, 23 mm) in nine patients. A blinded radiologist manually delineated all lymphomas on all slices. The manual result served as the ''gold standard'' for comparison. Several quantitative methods were applied to objectively evaluate the performance of the segmentation algorithm. The algorithm received a mean overlap, overestimation, and underestimation ratios of 83.2%, 13.5%, and 5.5%, respectively. The mean average boundary distance and Hausdorff boundary distance were 0.7 and 3.7 mm. Preliminary results have shown the potential of this computer algorithm to allow reliable segmentation and quantification of lymphomas on sequential CT images.

OSTI ID:
20853220
Journal Information:
Medical Physics, Vol. 33, Issue 7; Other Information: DOI: 10.1118/1.2207133; (c) 2006 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English