Mass Measurements with the CSS2 and CIME cyclotrons at GANIL
- University of Liverpool, Oliver Lodge Laboratory, L69 7ZE Liverpool (United Kingdom)
- GANIL, Bld Henri Becquerel, BP 5027, 14076 Caen Cedex 5 (France)
- CEN Bordeaux-Gradignan, Le Haut-Vigneau, 33175 Gradignan (France)
- IFIC, CSIC-Universidad de Valencia, E-46071 Valencia (Spain)
- CEA/DSM/DAPNIA/SPhN, CEN Saclay, 91191 Gif-sur-Yvette (France)
- IFUSP, Caixa Postal 66318, CEP 05315-970 Sao Paulo (Brazil)
- LPC, 6 Bld du Marechal Juin, 14050 Caen Cedex (France)
- Universita di Catania, 64 Via S. Sofia, 95123 Catania (Italy)
This paper presents two original direct mass-measurement techniques developed at GANIL using the CSS2 and CIME cyclotrons as high-resolution mass spectrometers. The mass measurement with the CSS2 cyclotron is based on a time-of-flight method along the spiral trajectory of the ions inside the cyclotron. The atomic mass excesses of 68Se and 80Y recently measured with this technique are -53.958(246) MeV and -60.971(180) MeV, respectively. The new mass-measurement technique with the CIME cyclotron is based on the sweep of the acceleration radio-frequency of the cyclotron. Tests with stable beams have been performed in order to study the accuracy of this new mass-measurement method and to understand the systematic errors.
- OSTI ID:
- 20798279
- Journal Information:
- AIP Conference Proceedings, Vol. 819, Issue 1; Conference: 12. international symposium on capture gamma-ray spectroscopy and related topics, Notre Dame, IN (United States), 4-9 Sep 2005; Other Information: DOI: 10.1063/1.2187851; (c) 2006 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
GANIL-SPIRAL1-SPIRAL2: Highlights and Perspectives
GANIL-SPIRAL2: A new era