skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Measurements and simulations of the ablation stage of wire arrays with different initial wire sizes

Journal Article · · Physics of Plasmas
DOI:https://doi.org/10.1063/1.2184307· OSTI ID:20782755
; ; ; ; ; ;  [1];  [2];  [3];  [4]
  1. Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185-1193 (United States)
  2. Blackett Laboratory, Imperial College, London SW7 2BW (United Kingdom)
  3. Ktech Corporation, 1300 Eubank Boulevard SE, Albuquerque, New Mexico 87123 (United States)
  4. Prism Computational Sciences, Madison, Wisconsin 53711 (United States)

Comparisons of 20 mm diameter, 300-wire tungsten arrays with different initial wire sizes were made on the 20 MA Sandia Z facility. Radiographic measurements of each wire array, taken at the same point in the current during the wire ablation stage, show systematic differences. A detailed comparison of the radiography and self-emission data with simulations and analytic models suggests that a variation in the mass ablation rate with wire size may be responsible.

OSTI ID:
20782755
Journal Information:
Physics of Plasmas, Vol. 13, Issue 4; Other Information: DOI: 10.1063/1.2184307; (c) 2006 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 1070-664X
Country of Publication:
United States
Language:
English