Decontamination of biological warfare agents by a microwave plasma torch
- Department of Electrical and Computer Engineering, Polytechnic University, New York 11201 (United States)
A portable arc-seeded microwave plasma torch running stably with airflow is described and applied for the decontamination of biological warfare agents. Emission spectroscopy of the plasma torch indicated that this torch produced an abundance of reactive atomic oxygen that could effectively oxidize biological agents. Bacillus cereus was chosen as a simulant of Bacillus anthracis spores for biological agent in the decontamination experiments. Decontamination was performed with the airflow rate of 0.393 l/s, corresponding to a maximum concentration of atomic oxygen produced by the torch. The experimental results showed that all spores were killed in less than 8 s at 3 cm distance, 12 s at 4 cm distance, and 16 s at 5 cm distance away from the nozzle of the torch.
- OSTI ID:
- 20698350
- Journal Information:
- Physics of Plasmas, Vol. 12, Issue 2; Other Information: DOI: 10.1063/1.1843131; (c) 2005 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 1070-664X
- Country of Publication:
- United States
- Language:
- English
Similar Records
A decontamination study of simulated chemical and biological agents
Decontamination Strategy for Large Area and/or Equipment Contaminated with Chemical and Biological Agents using a High Energy Arc Lamp (HEAL)