Characterization of diagnostic hole-closure in Z-pinch driven hohlraums
- Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States)
In this article we investigate the partial closure of diagnostic holes in Z-pinch driven hohlraums. These hohlraums differ from current laser-driven hohlraums in a number of ways such as their larger size, greater x-ray drive energy, and lower temperature. Although the diameter of the diagnostic holes on these Z-pinch driven hohlraums can be much greater than their laser-driven counterparts, 4 mm in diameter or larger, radiation impinges on the wall material surrounding the hole for the duration of the Z pinch, nearly 100 ns. This incident radiation causes plasma to ablate from the hohlraum walls surrounding the diagnostic hole and partially obscure this diagnostic hole. This partial obscuration reduces the effective area over which diagnostics view the hohlraum's radiation. This reduction in area can lead to an underestimation of the wall temperature when nonimaging diagnostics such as x-ray diodes and bolometers are used to determine power and later to infer a wall temperature. In this article we describe the techniques used to characterize the hole-closure in these hohlraums and present the experimental measurements of this process. (c) 2000 American Institute of Physics.
- OSTI ID:
- 20215197
- Journal Information:
- Physics of Plasmas, Vol. 7, Issue 2; Other Information: PBD: Feb 2000; ISSN 1070-664X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Soft X-Ray Measurements of Z-Pinch-Driven Vacuum Hohlraums
An imaging diode array soft x-ray diagnostic for Z (abstract)