Title: Thermal conductivity of ternary refrigerant mixtures of HFC-32/125/134a in the liquid phase

Journal Article · · International Journal of Thermophysics

The liquid thermal conductivity of two ternary mixtures of HFC-32/125/134a (23.0/25.0/52.0 and 19.0/43.8/37.2 wt%) was measured using a transient hotwire instrument in the temperature ranges from 193 to 293 K and from 213 to 293, respectively, and in the pressure range from 2 to 30 MPa. The thermal conductivity has an estimated uncertainty of {+-}7.0%. For engineering purposes, the thermal conductivity data were correlated using a polynomial in temperature and pressure for each mixture with a standard deviation of 0.6%.

Research Organization:
Keio Univ., Yokohama (JP)
OSTI ID:
20020842
Journal Information:
International Journal of Thermophysics, Vol. 20, Issue 5; Other Information: PBD: Sep 1999; ISSN 0195-928X
Country of Publication:
United States
Language:
English