Title: Shielding factors of grain oriented 3% SiFe cylinders

Abstract

The authors have measured the magnetic shielding factor and permeability of 3% SiFe cylinders with various diameters under the same test frequency, magnetization level, and geometry conditions. The measured shielding factor has been compared with the estimated one by using the measured permeability for the single- and double-layered cylinders. It is found that the simple permeability measurement of the cylinder in itself is useful for the prediction of a magnetic shielding factor.

Authors:
; ;
Publication Date:
Research Org.:
Korea Research Inst. of Standards and Science, Taejon (KR)
OSTI Identifier:
20000791
Resource Type:
Journal Article
Journal Name:
IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers)
Additional Journal Information:
Journal Volume: 35; Journal Issue: 5Pt2; Conference: 1999 international magnetics conference (Intermag '99), Kyongju (KR), 05/18/1999--05/21/1999; Other Information: PBD: Sep 1999; Journal ID: ISSN 0018-9464
Country of Publication:
United States
Language:
English
Subject:
36 MATERIALS SCIENCE; LOW ALLOY STEELS; SILICON ALLOYS; MAGNETIC SHIELDING; MAGNETIC SUSCEPTIBILITY; CYLINDERS

Citation Formats

Chung, Y.C., Woo, B.C., and Park, D.C. Shielding factors of grain oriented 3% SiFe cylinders. United States: N. p., 1999. Web. doi:10.1109/20.800555.
Chung, Y.C., Woo, B.C., & Park, D.C. Shielding factors of grain oriented 3% SiFe cylinders. United States. doi:10.1109/20.800555.
Chung, Y.C., Woo, B.C., and Park, D.C. Wed . "Shielding factors of grain oriented 3% SiFe cylinders". United States. doi:10.1109/20.800555.
@article{osti_20000791,
title = {Shielding factors of grain oriented 3% SiFe cylinders},
author = {Chung, Y.C. and Woo, B.C. and Park, D.C.},
abstractNote = {The authors have measured the magnetic shielding factor and permeability of 3% SiFe cylinders with various diameters under the same test frequency, magnetization level, and geometry conditions. The measured shielding factor has been compared with the estimated one by using the measured permeability for the single- and double-layered cylinders. It is found that the simple permeability measurement of the cylinder in itself is useful for the prediction of a magnetic shielding factor.},
doi = {10.1109/20.800555},
journal = {IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers)},
issn = {0018-9464},
number = 5Pt2,
volume = 35,
place = {United States},
year = {1999},
month = {9}
}