Title: The use of polyurethane foam to provide a watertight concrete masonry wall and a sealed connection of the wall to the foundation

Conference ·
OSTI ID:20000681

This paper outlines a construction procedure used to insure a watertight masonry wall and a sealed connection, of this same wall, to the foundation. This procedure was discovered as the byproduct of using an insulted dual cavity concrete masonry unit that is foamed in the field. This insulated concrete masonry system has been developed in the past 12 years, and has been utilized in almost 100 buildings (in Arizona, California, Nevada, Oregon, and Utah) with climates that range from hot desert to Sierra Nevada snow country to the Pacific Northwest rainfall. The critical elements in perfecting this procedure are the detailing of the base of the wall, with a continuous exterior first course foam side cleanout, then following this detailing in the field construction of the wall, and properly foaming the constructed wall with polyurethane foam. The polyurethane foam must be poured into the foam cavity after the face shells have been replace at the first course cleanout.

Research Organization:
Graystone Block Co., Inc., Modesto, CA (US)
OSTI ID:
20000681
Report Number(s):
CONF-9804139-; ISBN 0-8031-2607-7
Resource Relation:
Conference: Water Problems in Building Exterior Walls: Evaluation, Prevention, and Repair, Atlanta, GA (US), 04/18/1998--04/19/1998; Other Information: PBD: 1999; Related Information: In: Water problems in building exterior walls: Evaluation, prevention, and repair. ASTM special technical publication 1352, by Boyd, J.M.; Scheffler, M.J. [eds.], 342 pages.
Country of Publication:
United States
Language:
English