Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Pros and Cons Analysis of HALEU Utilization in Example Fuel Cycles

Technical Report ·
DOI:https://doi.org/10.2172/1985692· OSTI ID:1985692
 [1];  [1];  [2];  [3]
  1. Argonne National Laboratory (ANL), Argonne, IL (United States)
  2. Idaho National Laboratory (INL), Idaho Falls, ID (United States)
  3. Brookhaven National Laboratory (BNL), Upton, NY (United States)

The Systems Analysis and Integration campaign assessed the pros and cons of high-assay low-enriched uranium (HALEU) utilization in advanced reactors and associated fuel cycles. The assessment was done for three example fuel cycles at equilibrium states: once-through, limited recycle, and continuous recycle (CR) starting with HALEU. Front- and back-end fuel cycle parameters and the Levelized Cost of Fuel (LCF), which is the Levelized Cost of Electricity excluding reactor cost, of the three example fuel cycles were calculated using a single Analysis Example Reactor. The pros and cons of HALEU utilization were assessed by normalizing the fuel cycle parameters and LCF to a unit of electricity generation (GWe-year) and comparing them with a Basis of Comparison. In this study, a sodium-cooled reactor with sodium-bonded metallic fuel having a burnup of ~100 GWd/t was used as the Analysis Example Reactor because its technology readiness level is high, and the burnup and fuel enrichment are in the middle of those ranges of advanced reactor concepts that are under development. The current once-through Light Water Reactors (OT-LWRs) with <5% low-enriched uranium and 50 GWd/t burnup were used as the Basis of Comparison. In addition, a series of sensitivity analyses was conducted by varying burnup, enrichment, fuel forms, and reactor types to capture the design variations in two once-through Advanced Reactor Demonstration Program (ARDP) reactors, Natrium with sodium-free metallic fuel having a burnup of ~150 GW/t and Xe-100 with Tristructural-Isotropic (TRISO) pebble fuel having a burnup of ~168 GWd/t.

Research Organization:
Argonne National Laboratory (ANL), Argonne, IL (United States)
Sponsoring Organization:
USDOE Office of Nuclear Energy (NE)
DOE Contract Number:
AC02-06CH11357
OSTI ID:
1985692
Report Number(s):
ANL/NSE--22/21; 182926
Country of Publication:
United States
Language:
English

Similar Records

Report on Fuel Cycle Facility Requirements for Deployment of Demonstration Reactors and Potential Evolutionary Fuel Cycle Scenarios
Technical Report · Sun Nov 27 23:00:00 EST 2022 · OSTI ID:1903005

Assessment of Deep Burnup HALEU Fuel Impact and Requirements
Technical Report · Wed Jul 30 20:00:00 EDT 2025 · OSTI ID:3005957

Values of Recovered Uranium from HALEU Used Nuclear Fuels (Rev. 1)
Technical Report · Thu Mar 28 00:00:00 EDT 2024 · OSTI ID:2340136