Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Resolving Power and Collision Cross Section Measurement Accuracy of a Prototype High-Resolution Ion Mobility Platform Incorporating Structures for Lossless Ion Manipulation

Journal Article · · Journal of the American Society for Mass Spectrometry
 [1];  [1];  [1];  [2];  [2];  [2];  [2];  [1]
  1. Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, Tenessee 37235, United States
  2. MOBILion Systems, Chadds Ford, Pennsylvania 19317, United States

Not provided.

Research Organization:
Vanderbilt Univ., Nashville, TN (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
DOE Contract Number:
SC0019404
OSTI ID:
1853209
Journal Information:
Journal of the American Society for Mass Spectrometry, Vol. 32, Issue 4; ISSN 1044-0305
Publisher:
American Society for Mass Spectrometry
Country of Publication:
United States
Language:
English

References (65)

Advanced Multidimensional Separations in Mass Spectrometry: Navigating the Big Data Deluge journal June 2016
Ion Mobility-Mass Spectrometry: Time-Dispersive Instrumentation journal January 2015
Size, weight and position: ion mobility spectrometry and imaging MS combined journal January 2011
Ion Mobility Derived Collision Cross Sections to Support Metabolomics Applications journal March 2014
Untargeted Molecular Discovery in Primary Metabolism: Collision Cross Section as a Molecular Descriptor in Ion Mobility-Mass Spectrometry journal November 2018
Combining Glucose Units, m / z , and Collision Cross Section Values: Multiattribute Data for Increased Accuracy in Automated Glycosphingolipid Glycan Identifications and Its Application in Triple Negative Breast Cancer journal June 2019
Characterizing the resolution and accuracy of a second-generation traveling-wave ion mobility separator for biomolecular ions journal January 2011
Broadscale resolving power performance of a high precision uniform field ion mobility-mass spectrometer journal January 2015
Does the ion mobility resolving power as provided by commercially available ion mobility quadrupole time-of-flight mass spectrometry instruments permit the unambiguous identification of small molecules in complex matrices? journal April 2020
Isomer separation of polybrominated diphenyl ether metabolites using nanoESI-TIMS-MS journal April 2016
Trapped ion mobility spectrometry: A short review journal February 2018
A Cyclic Ion Mobility-Mass Spectrometry System journal May 2019
Characterization of Ion Dynamics in Structures for Lossless Ion Manipulations journal September 2014
New frontiers for mass spectrometry based upon structures for lossless ion manipulations journal January 2017
Opening new paths for biological applications of ion mobility - Mass spectrometry using structures for lossless ion manipulations journal July 2019
Ion Trapping, Storage, and Ejection in Structures for Lossless Ion Manipulations journal May 2015
Mobility-Selected Ion Trapping and Enrichment Using Structures for Lossless Ion Manipulations journal January 2016
Experimental Evaluation and Optimization of Structures for Lossless Ion Manipulations for Ion Mobility Spectrometry with Time-of-Flight Mass Spectrometry journal September 2014
Ion manipulations in structures for lossless ion manipulations (SLIM): computational evaluation of a 90° turn and a switch journal January 2015
Mobility-Resolved Ion Selection in Uniform Drift Field Ion Mobility Spectrometry/Mass Spectrometry: Dynamic Switching in Structures for Lossless Ion Manipulations journal September 2014
Ion Elevators and Escalators in Multilevel Structures for Lossless Ion Manipulations journal January 2017
Ultra-High-Resolution Ion Mobility Separations Over Extended Path Lengths and Mobility Ranges Achieved using a Multilevel Structures for Lossless Ion Manipulations Module journal May 2020
Simulation of Electric Potentials and Ion Motion in Planar Electrode Structures for Lossless Ion Manipulations (SLIM) journal September 2014
Characterization of Traveling Wave Ion Mobility Separations in Structures for Lossless Ion Manipulations journal October 2015
Achieving High Resolution Ion Mobility Separations Using Traveling Waves in Compact Multiturn Structures for Lossless Ion Manipulations journal August 2016
A simulation study of the influence of the traveling wave patterns on ion mobility separations in structures for lossless ion manipulations journal January 2020
Applications of a travelling wave-based radio-frequency-only stacked ring ion guide
  • Giles, Kevin; Pringle, Steven D.; Worthington, Kenneth R.
  • Rapid Communications in Mass Spectrometry, Vol. 18, Issue 20, p. 2401-2414 https://doi.org/10.1002/rcm.1641
journal October 2004
Ion Mobility Separations of Isomers based upon Long Path Length Structures for Lossless Ion Manipulations Combined with Mass Spectrometry journal July 2016
Ultra-High Resolution Ion Mobility Separations Utilizing Traveling Waves in a 13 m Serpentine Path Length Structures for Lossless Ion Manipulations Module journal August 2016
Correlating Resolving Power, Resolution, and Collision Cross Section: Unifying Cross-Platform Assessment of Separation Efficiency in Ion Mobility Spectrometry journal October 2017
Serpentine Ultralong Path with Extended Routing (SUPER) High Resolution Traveling Wave Ion Mobility-MS using Structures for Lossless Ion Manipulations journal April 2017
Lipid and Glycolipid Isomer Analyses Using Ultra-High Resolution Ion Mobility Spectrometry Separations journal January 2017
SLIM Ultrahigh Resolution Ion Mobility Spectrometry Separations of Isotopologues and Isotopomers Reveal Mobility Shifts due to Mass Distribution Changes journal August 2019
A Hybrid Constant and Oscillatory Field Ion Mobility Analyzer Using Structures for Lossless Ion Manipulations journal December 2017
Squeezing of Ion Populations and Peaks in Traveling Wave Ion Mobility Separations and Structures for Lossless Ion Manipulations Using Compression Ratio Ion Mobility Programming journal November 2016
Compression Ratio Ion Mobility Programming (CRIMP) Accumulation and Compression of Billions of Ions for Ion Mobility-Mass Spectrometry Using Traveling Waves in Structures for Lossless Ion Manipulations (SLIM) journal May 2017
Design of a TW-SLIM Module for Dual Polarity Confinement, Transport, and Reactions journal May 2017
Dual Polarity Ion Confinement and Mobility Separations journal March 2019
Traveling-Wave-Based Electrodynamic Switch for Concurrent Dual-Polarity Ion Manipulations in Structures for Lossless Ion Manipulations journal October 2019
Automated flow injection method for the high precision determination of drift tube ion mobility collision cross sections journal January 2018
Welcome to the Tidyverse journal November 2019
Measuring the Resolving Power of Ion Mobility Spectrometers journal December 1994
Conformational Ordering of Biomolecules in the Gas Phase: Nitrogen Collision Cross Sections Measured on a Prototype High Resolution Drift Tube Ion Mobility-Mass Spectrometer journal February 2014
An Interlaboratory Evaluation of Drift Tube Ion Mobility–Mass Spectrometry Collision Cross Section Measurements journal August 2017
Fundamentals of Traveling Wave Ion Mobility Spectrometry journal December 2008
Resolution of Isomeric Mixtures in Ion Mobility Using a Combined Demultiplexing and Peak Deconvolution Technique journal July 2020
Deciphering Drift Time Measurements from Travelling Wave Ion Mobility Spectrometry-Mass Spectrometry Studies journal April 2009
Classical aspects of the reduced collision cross section for elastic scattering in ion mobility spectrometry journal January 2013
Uncertainty Estimations for Collision Cross Section Determination via Uniform Field Drift Tube-Ion Mobility-Mass Spectrometry journal August 2020
Assessing Collision Cross Section Calibration Strategies for Traveling Wave-Based Ion Mobility Separations in Structures for Lossless Ion Manipulations journal November 2020
Fundamentals of travelling wave ion mobility revisited: I. Smoothly moving waves journal May 2018
The influence of drift gas composition on the separation mechanism in traveling wave ion mobility spectrometry: insight from electrodynamic simulations journal February 2013
Separation of Isomeric Peptides Using Electrospray Ionization/High-Resolution Ion Mobility Spectrometry journal January 2000
A new, higher resolution, ion mobility mass spectrometer journal October 2009
Enhancements in travelling wave ion mobility resolution
  • Giles, Kevin; Williams, Jonathan P.; Campuzano, Iain
  • Rapid Communications in Mass Spectrometry, Vol. 25, Issue 11, p. 1559-1566 https://doi.org/10.1002/rcm.5013
journal May 2011
Atmospheric Pressure Drift Tube Ion Mobility–Orbitrap Mass Spectrometry: Initial Performance Characterization journal October 2017
Oversampling Selective Accumulation Trapped Ion Mobility Spectrometry Coupled to FT-ICR MS: Fundamentals and Applications journal July 2016
Evaluation of drift gas selection in complex sample analyses using a high performance drift tube ion mobility-QTOF mass spectrometer journal January 2015
High-Resolution Ion Cyclotron Mobility Spectrometry journal February 2009
Rapid and sensitive differentiation of anomers, linkage, and position isomers of disaccharides using High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) journal March 2003
Separation of sodiated isobaric disaccharides and trisaccharides using electrospray ionization-atmospheric pressure ion mobility-time of flight mass spectrometry journal May 2005
Direct Infusion Electrospray Ionization – Ion Mobility – High Resolution Mass Spectrometry (DIESI-IM-HRMS) for Rapid Characterization of Potential Bioprocess Streams journal May 2012
Ion Mobility Studies of Carbohydrates as Group I Adducts: Isomer Specific Collisional Cross Section Dependence on Metal Ion Radius journal September 2013
Detection of Individual Phospholipids in Lipid Mixtures by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry: Phosphatidylcholine Prevents the Detection of Further Species journal February 2001
A relative quantitative positive/negative ion switching method for untargeted lipidomics via high resolution LC-MS/MS from any biological source journal February 2017