Title: AATTENUATION—The Atmospheric Attenuation Model for CSP Tower Plants: A Look-Up Table for Operational Implementation

Journal Article · · Energies (Basel)
DOI:https://doi.org/10.3390/en13205248· OSTI ID:1710191
 [1];  [2]; ORCiD logo [1];  [3];  [4]
  1. German Aerospace Center (DLR), Almeria (Spain)
  2. Green Energy Park (IRESEN, UM6P), Benguerir (Morocco)
  3. National Renewable Energy Lab. (NREL), Golden, CO (United States)
  4. Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Madrid (Spain)

Attenuation of solar radiation between the receiver and the heliostat field in concentrated solar power (CSP) tower plants can reduce the overall system performance significantly. The attenuation varies strongly with time and the average attenuation at different sites might also vary strongly from each other. If no site specific attenuation data is available, the optimal plant design cannot be determined and rough estimations of the attenuation effect are required leading to high uncertainties of yield analysis calculations. The attenuation is caused mainly by water vapor content and aerosol particles in the lower atmospheric layer above ground. Although several on-site measurement systems have been developed during recent years, attenuation data sets are usually not available to be included during the plant project development. An Atmospheric Attenuation (AATTENUATION) model to derive the atmospheric transmittance between a heliostat and receiver on the basis of common direct normal irradiance (DNI), temperature, relative humidity, and barometric pressure measurements was developed and validated by the authors earlier. The model allows the accurate estimation of attenuation for sites with low attenuation and gives an estimation of the attenuation for less clear sites. However, the site-dependent coefficients of the AATTENUATION model had to be developed individually for each site of interest, which required time-consuming radiative transfer simulations, considering the exact location and altitude, as well as the pre-dominant aerosol type at the location. This strongly limited the application of the model despite its typically available input data. In this manuscript, a look-up table (LUT) is presented which enables the application of the AATTENUATION model at the site of interest without the necessity to perform the according complex radiative transfer calculations for each site individually. This enables the application of the AATTENUATION model for virtually all resource assessments for tower plants and in an operational mode in real time within plant monitoring systems around the world. The LUT also facilitates the generation of solar attenuation maps on the basis of long-term meteorological data sets which can be considered during resource assessment for CSP tower plant projects. The LUTs are provided together with this manuscript as supplementary files. The LUT for the AATTENUATION model was developed for a solar zenith angle (SZA) grid of 1°, an altitude grid of 100 m, 7 different standard aerosol types and the standard AFGL atmospheres for mid-latitudes and the tropics. The LUT was tested against the original version of the AATTENUATION model at 4 sites in Morocco and Spain, and it was found that the additional uncertainty introduced by the application of the LUT is negligible. With the information of latitude, longitude, altitude above mean sea level, DNI, relative humidity (RH), ambient temperature (Tair), and barometric pressure (bp), the attenuation can be now derived easily for each site of interest.

Research Organization:
National Renewable Energy Laboratory (NREL), Golden, CO (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE); Federal Ministry of Education and Research (BMBF)
Grant/Contract Number:
AC36-08GO28308; 1DH17003
OSTI ID:
1710191
Report Number(s):
NREL/JA-5D00-78281; MainId:32198; UUID:dbe4733f-3571-4ca8-9f9a-d3f1234ea3d2; MainAdminID:18794
Journal Information:
Energies (Basel), Vol. 13, Issue 20; ISSN 1996-1073
Publisher:
MDPI AGCopyright Statement
Country of Publication:
United States
Language:
English

References (27)

Stochastic theory of radiative transfer through generalized cloud fields journal January 2004
Modeling water vapor impacts on the solar irradiance reaching the receiver of a solar tower plant by means of artificial neural networks journal July 2018
A new airmass independent formulation for the Linke turbidity coefficient journal September 2002
Assessment of the Accuracy and Computing Speed of Simplified Saturation Vapor Equations Using a New Reference Dataset journal July 1993
Analysis of solar tower plant performance influenced by atmospheric attenuation at different temporal resolutions related to aerosol optical depth journal November 2017
Modeling beam attenuation in solar tower plants using common DNI measurements journal May 2016
The SG2 algorithm for a fast and accurate computation of the position of the Sun for multi-decadal time period journal October 2012
Atmospheric extinction in solar tower plants – A review journal August 2017
Stochastic model to describe atmospheric attenuation from yearly global solar irradiation journal February 2015
A comprehensive review of state-of-the-art concentrating solar power (CSP) technologies: Current status and research trends journal August 2018
Technical note: The libRadtran software package for radiative transfer calculations - description and examples of use journal January 2005
Atmospheric Transmittance Model Validation for CSP Tower Plants journal May 2019
The Astronomical Almanac's algorithm for approximate solar position (1950–2050) journal January 1988
Heat Transfer Phenomena in Concentrating Solar Power Systems. report November 2016
Dust-Storm Source Areas Determined by the Total Ozone Monitoring Spectrometer and Surface Observations journal June 2003
Modelling atmospheric attenuation at different AOD time-scales in yield performance of solar tower plants
  • Polo, Jesús; Alonso-Montesinos, Joaquin; López-Rodriguez, Gabriel
  • SolarPACES 2017: International Conference on Concentrating Solar Power and Chemical Energy Systems, AIP Conference Proceedings https://doi.org/10.1063/1.5067198
conference January 2018
The libRadtran software package for radiative transfer calculations (version 2.0.1) journal January 2016
Atmospheric extinction levels of solar radiation at Plataforma Solar de Almería. Application to solar thermal electric plants journal February 2018
Analysis of monthly average atmospheric precipitable water and turbidity in Canada and Northern United States journal July 1994
Sensitivity study for modelling atmospheric attenuation of solar radiation with radiative transfer models and the impact in solar tower plant production journal September 2016
New secondary-scattering correction in DISORT with increased efficiency for forward scattering journal August 2011
Representative wavelengths absorption parameterization applied to satellite channels and spectral bands journal November 2014
Optical Properties of Aerosols and Clouds: The Software Package OPAC journal May 1998
Numerically stable algorithm for discrete-ordinate-method radiative transfer in multiple scattering and emitting layered media journal January 1988
Atmospheric extinction in solar tower plants: absorption and broadband correction for MOR measurements journal January 2015
Atmospheric transmission loss in mirror-to-tower slant ranges due to water vapor
  • Gueymard, Christian A.; López, Gabriel; Rapp-Arrarás, Igor
  • SOLARPACES 2016: International Conference on Concentrating Solar Power and Chemical Energy Systems, AIP Conference Proceedings https://doi.org/10.1063/1.4984518
conference January 2017
Solar energy incident at the receiver of a solar tower plant, derived from remote sensing: Computation of both DNI and slant path transmittance
  • Elias, Thierry; Ramon, Didier; Garnero, Marie-Agnès
  • SOLARPACES 2016: International Conference on Concentrating Solar Power and Chemical Energy Systems, AIP Conference Proceedings https://doi.org/10.1063/1.4984513
conference January 2017