skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Non-Contact Vapor Detection of Illicit Drugs via Atmospheric Flow Tube-Mass Spectrometry

Journal Article · · Analyst
DOI:https://doi.org/10.1039/D0AN00691B· OSTI ID:1686083

Real-time, non-contact detection of illicit drugs is a desirable goal for the interdiction of these controlled substances, but the relatively low vapor pressures of such species present a challenge for trace vapor detection technologies. The introduction of atmospheric flow tube-mass spectrometry (AFT-MS), which has previously been demonstrated to detect gas-phase analytes at low parts-per-quadrillion levels for explosives and organophosphorus compounds, also enables the potential for non-contact drug detection. With AFT-MS, direct vapor detection of cocaine and methamphetamine from ~5 µg residues at room temperature is demonstrated herein. Furthermore, thermal desorption of low- to sub-picogram levels of cocaine, methamphetamine, fentanyl, and heroin is observed via AFT-MS using a carrier flow rate of several L/min of air. These low levels can permit non-contact sampling through collection of vapor, effectively preconcentrating the analyte before desorption and analysis. Quantitative evaluation of the thermal desorption approach has yielded limits of detection (LODs) on order of 10 fg for cocaine and fentanyl, 100 fg for methamphetamine, and 1.6 pg for heroin. The LOD for heroin was lowered to 200 fg by using tributyl phosphate as a dopant to form a proton-bound heterodimer with heroin. When used with AFT-MS, the intentional formation of specific drug-dopant adducts has the potential to enhance detection limits and selectivity of additional drug species. Species that are prone to form adducts present a challenge to analysis, but that difficulty can be overcome by the intentional addition of a dopant. Molecules unlikely to form adducts will remain essentially unimpacted, but the adduct-forming species will interact with the dopant to compress the analyte signal into a single peak. This approach would be valuable in the application of non-contact screening for illicit substances via vapor collection followed by thermal desorption for analysis.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
1686083
Report Number(s):
PNNL-SA-154280
Journal Information:
Analyst, Vol. 145, Issue 20
Country of Publication:
United States
Language:
English

References (28)

ACMT and AACT position statement: preventing occupational fentanyl and fentanyl analog exposure to emergency responders journal September 2017
Determination of amphetamine, cocaine, and heroin vapour pressures using a dynamic gas blending system and gas chromatographic analysis journal October 1984
Vapor Pressure and Enthalpy of Vaporization of Fentanyl journal March 2008
Determination of cocaine and heroin vapor pressures using commercial and illicit samples journal January 2000
Gas phase detection of cocaine by means of immunoanalysis journal January 1996
Broad spectrum infrared thermal desorption of wipe-based explosive and narcotic samples for trace mass spectrometric detection journal January 2017
Sensitive detection of drug vapors using an ion funnel interface for secondary electrospray ionization mass spectrometry: EESI-MS of drug vapors using an ion funnel journal May 2012
Gas chromatography–full scan mass spectrometry determination of traces of chemical warfare agents and their impurities in air samples by inlet based thermal desorption of sorbent tubes journal February 2012
Direct Real-Time Detection of RDX Vapors Under Ambient Conditions journal December 2012
Direct Real-Time Detection of Vapors from Explosive Compounds journal October 2013
Detection of Inorganic Salt-Based Homemade Explosives (HME) by Atmospheric Flow Tube–Mass Spectrometry journal May 2018
Characterization of alkylphosphonic acid vapors using atmospheric flow tube-ion trap mass spectrometry journal July 2018
Interrogating Proton Affinities of Organophosphonate Species Via Atmospheric Flow Tube Mass Spectrometry and Computational Methods journal April 2019
Selective Reagent Ions for the Direct Vapor Detection of Organophosphorus Compounds Below Parts-per-Trillion Levels journal May 2018
Ambient vapor sampling and selective cluster formation for the trace detection of tributyl phosphate via atmospheric flow tube mass spectrometry journal April 2019
Rapid pre-filtering of amphetamine and derivatives by direct analysis in real time (DART)-differential mobility spectrometry (DMS) journal January 2017
Direct Mass Spectrometry Analysis of Complex Mixtures by Nanoelectrospray with Simultaneous Atmospheric Pressure Chemical Ionization and Electrophoretic Separation Capabilities journal August 2019
Characterization of Solid Counterfeit Drug Samples by Desorption Electrospray Ionization and Direct-analysis-in-real-time Coupled to Time-of-flight Mass Spectrometry journal July 2006
The Ionic Hydrogen Bond journal January 2005
Proton-bound cluster ions in ion mobility spectrometry journal October 1999
Hydration Structure of Cocaine and its Metabolites: A Molecular Dynamics Study journal March 2011
On the effects of the basis set superposition error on the change of QTAIM charges in adduct formation. Application to complexes between morphine and cocaine and their main metabolites journal January 2016
On the Electronic Structure of Cocaine and its Metabolites
  • Rincón, David A.; Dias Soeiro Cordeiro, Maria Natália; Mosquera, Ricardo A.
  • The Journal of Physical Chemistry A, Vol. 113, Issue 50 https://doi.org/10.1021/jp9056048
journal December 2009
Theoretical study of cocaine and ecgonine methyl ester in gas phase and in aqueous solution journal January 2009
A conformational study of cocaine and its diastereomers journal October 1990
First-principle studies of intermolecular and intramolecular catalysis of protonated cocaine journal January 2005
The crystal and molecular structure of l -cocaine hydrochloride journal August 1963
The vaporization enthalpy and vapor pressure of S (+)-methamphetamine at T=298.15K by correlation gas chromatography journal June 2014