Interaction region vacuum system design at the PEP-II B factory
The Interaction Region Vacuum System in the PEP-II B-Factory at SLAC must produce average pressures in the 10{sup -10} Torr range. low beamline pressures will minimize the background radiation encountered by the BaBar Detector A combination of copper and stainless steel vacuum chambers with continuous antechambers are used to make up the beam tubes. Linear Non-Evaporable Getter (NEG) pumps are used to produce distributed pumping along the length of these beam tubes. High conductance microwave type screens provide RF shields between the beam aperture and the NEG pumps. In this paper the design features of the beam tubes, NEG pumps, and RF pump screens are described and the vacuum and impedance analyses conducted in support of the design are discussed.
- Sponsoring Organization:
- (US)
- DOE Contract Number:
- W-7405-Eng-48
- OSTI ID:
- 16393
- Report Number(s):
- UCRL-JC-128067; CONF-970503*-; ON: DE98051012; TRN: US200302%%631
- Resource Relation:
- Conference: 1997 Particle Accelerator Conference, Vancouver, BC (CA), 05/12/1997--05/16/1997; Other Information: Supercedes report DE98051012; PBD: 21 Jul 97; PBD: 21 Jul 1997
- Country of Publication:
- United States
- Language:
- English