The Integrable Optics Test Accelerator is a research electron and proton storage ring recently commissioned at the Fermilab Accelerator Science and Technology facility. A key part of its beam diagnostics suite are synchrotron radiation monitors, used for measuring transverse beam profile, position, and intensity. In this paper, we report on the performance and uses of this system during the year 1 run. We demonstrate sub-100nm statistical beam position uncertainty and high dynamic range from 10⁹ electrons down to a single electron. Commissioning challenges and operational issues are discussed. We conclude by outlining current upgrade efforts, including improved modularity, small emittance measurements, and a multi-anode photomultiplier system for turn-by-turn acquisition.

Authors:
 [1];  [2]; ORCiD logo [1]; ORCiD logo [2]; ORCiD logo [2]; ORCiD logo [2]
  1. Chicago U.
  2. Fermilab
Publication Date:
Research Org.:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Org.:
USDOE Office of Science (SC), High Energy Physics (HEP) (SC-25)
OSTI Identifier:
1576539
Report Number(s):
FERMILAB-CONF-19-340-AD-APC
oai:inspirehep.net:1745379
DOE Contract Number:  
AC02-07CH11359
Resource Type:
Conference
Resource Relation:
Conference: 10th International Particle Accelerator Conference, Melbourne, Australia, 05/19-05/24/2019
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS

Citation Formats

Kuklev, Nikita, Jarvis, Jonathan, Kim, Young-Kee, Romanov, Alexander, Santucci, James, and Stancari, Giulio. Synchrotron Radiation Beam Diagnostics at IOTA - Commissioning Performance and Upgrade Efforts. United States: N. p., 2019. Web. doi:10.18429/JACoW-IPAC2019-WEPGW103.
Kuklev, Nikita, Jarvis, Jonathan, Kim, Young-Kee, Romanov, Alexander, Santucci, James, & Stancari, Giulio. Synchrotron Radiation Beam Diagnostics at IOTA - Commissioning Performance and Upgrade Efforts. United States. doi:10.18429/JACoW-IPAC2019-WEPGW103.
Kuklev, Nikita, Jarvis, Jonathan, Kim, Young-Kee, Romanov, Alexander, Santucci, James, and Stancari, Giulio. Mon . "Synchrotron Radiation Beam Diagnostics at IOTA - Commissioning Performance and Upgrade Efforts". United States. doi:10.18429/JACoW-IPAC2019-WEPGW103. https://www.osti.gov/servlets/purl/1576539.
@article{osti_1576539,
title = {Synchrotron Radiation Beam Diagnostics at IOTA - Commissioning Performance and Upgrade Efforts},
author = {Kuklev, Nikita and Jarvis, Jonathan and Kim, Young-Kee and Romanov, Alexander and Santucci, James and Stancari, Giulio},
abstractNote = {The Integrable Optics Test Accelerator is a research electron and proton storage ring recently commissioned at the Fermilab Accelerator Science and Technology facility. A key part of its beam diagnostics suite are synchrotron radiation monitors, used for measuring transverse beam profile, position, and intensity. In this paper, we report on the performance and uses of this system during the year 1 run. We demonstrate sub-100nm statistical beam position uncertainty and high dynamic range from 10⁹ electrons down to a single electron. Commissioning challenges and operational issues are discussed. We conclude by outlining current upgrade efforts, including improved modularity, small emittance measurements, and a multi-anode photomultiplier system for turn-by-turn acquisition.},
doi = {10.18429/JACoW-IPAC2019-WEPGW103},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2019},
month = {6}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: