TRA-608: Reverse Osmosis (RO) Efficiency Analysis
Program Document
·
OSTI ID:1545536
- Idaho National Laboratory
Since its installation in the early 2000's, the RO system located in TRA-608 has not had an efficiency analysis performed on its RO membranes. This poster serves as a visual representation of the procedures and findings that resulted from conducting the analysis. Findings concluded that the membranes in units 1, 2, and 3 operated at efficiencies of about 74%, 72%, and 67%, respectively as of July 2019.