skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: High resolution, high signal-to-noise crystal spectrometer for measurements of line shifts in high-density plasmas

Abstract

The Orion high-resolution x-ray (OHREX) spectrometer has been a successful tool for measuring the shapes of density-broadened spectral lines produced in short-pulse heated plasmas at the Orion laser facility. We have recently outfitted the instrument with a charge-couple device (CCD) camera, which greatly increased the accuracy with which we can perform line-shift measurements. Because OHREX is located on the outside of the Orion target chamber, no provisions for the shielding of electromagnetic pulses are required. With the CCD, we obtained a higher signal-to-noise ratio than we previously obtained with an image-plate detector. As a result, this allowed us to observe structure in the image produced by the diffraction from the two OHREX crystals, which was highly reproducible from shot to shot. This structure will ultimately limit the accuracy of our spectroscopic measurements

Authors:
ORCiD logo [1];  [1];  [1];  [1];  [1];  [1];  [2];  [2]; ORCiD logo [2]; ORCiD logo [2];  [2]; ORCiD logo [2]
  1. Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
  2. AWE plc, Reading (United Kingdom)
Publication Date:
Research Org.:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Org.:
USDOE Office of Science (SC); USDOE National Nuclear Security Administration (NNSA)
OSTI Identifier:
1545369
Alternate Identifier(s):
OSTI ID: 1562806
Report Number(s):
LLNL-JRNL-749819
Journal ID: ISSN 0034-6748
Grant/Contract Number:  
AC52-07NA27344
Resource Type:
Journal Article: Accepted Manuscript
Journal Name:
Review of Scientific Instruments
Additional Journal Information:
Journal Volume: 89; Journal Issue: 10; Journal ID: ISSN 0034-6748
Publisher:
American Institute of Physics (AIP)
Country of Publication:
United States
Language:
English
Subject:
Physics - Atomic and molecular physics, Physics - Plasma physics

Citation Formats

Beiersdorfer, P., Magee, E. W., Brown, G. V., Hell, N., McKelvey, A., Shepherd, R., Hoarty, D. J., Brown, C. R. D., Hill, M. P., Hobbs, L. M. R., James, S. F., and Wilson, L. High resolution, high signal-to-noise crystal spectrometer for measurements of line shifts in high-density plasmas. United States: N. p., 2018. Web. doi:10.1063/1.5035303.
Beiersdorfer, P., Magee, E. W., Brown, G. V., Hell, N., McKelvey, A., Shepherd, R., Hoarty, D. J., Brown, C. R. D., Hill, M. P., Hobbs, L. M. R., James, S. F., & Wilson, L. High resolution, high signal-to-noise crystal spectrometer for measurements of line shifts in high-density plasmas. United States. doi:10.1063/1.5035303.
Beiersdorfer, P., Magee, E. W., Brown, G. V., Hell, N., McKelvey, A., Shepherd, R., Hoarty, D. J., Brown, C. R. D., Hill, M. P., Hobbs, L. M. R., James, S. F., and Wilson, L. Fri . "High resolution, high signal-to-noise crystal spectrometer for measurements of line shifts in high-density plasmas". United States. doi:10.1063/1.5035303. https://www.osti.gov/servlets/purl/1545369.
@article{osti_1545369,
title = {High resolution, high signal-to-noise crystal spectrometer for measurements of line shifts in high-density plasmas},
author = {Beiersdorfer, P. and Magee, E. W. and Brown, G. V. and Hell, N. and McKelvey, A. and Shepherd, R. and Hoarty, D. J. and Brown, C. R. D. and Hill, M. P. and Hobbs, L. M. R. and James, S. F. and Wilson, L.},
abstractNote = {The Orion high-resolution x-ray (OHREX) spectrometer has been a successful tool for measuring the shapes of density-broadened spectral lines produced in short-pulse heated plasmas at the Orion laser facility. We have recently outfitted the instrument with a charge-couple device (CCD) camera, which greatly increased the accuracy with which we can perform line-shift measurements. Because OHREX is located on the outside of the Orion target chamber, no provisions for the shielding of electromagnetic pulses are required. With the CCD, we obtained a higher signal-to-noise ratio than we previously obtained with an image-plate detector. As a result, this allowed us to observe structure in the image produced by the diffraction from the two OHREX crystals, which was highly reproducible from shot to shot. This structure will ultimately limit the accuracy of our spectroscopic measurements},
doi = {10.1063/1.5035303},
journal = {Review of Scientific Instruments},
issn = {0034-6748},
number = 10,
volume = 89,
place = {United States},
year = {2018},
month = {10}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 1 work
Citation information provided by
Web of Science

Save / Share:

Works referenced in this record:

A theoretical study of the plasma broadening of helium-like transitions for high-Z emitters
journal, October 1979

  • Lee, R. W.; Bromage, G. E.; Richards, A. G.
  • Journal of Physics B: Atomic and Molecular Physics, Vol. 12, Issue 20
  • DOI: 10.1088/0022-3700/12/20/022

K ‐ and L ‐shell x‐ray spectroscopy of indirectly driven implosions (invited)
journal, October 1992

  • Hammel, B. A.; Keane, C. J.; Kania, D. R.
  • Review of Scientific Instruments, Vol. 63, Issue 10
  • DOI: 10.1063/1.1143477

C vi Lyman line profiles from 10-ps KrF-laser-produced plasmas
journal, October 1995


Experimental evidence for plasma shifts in Lyman series of aluminum
journal, March 1998

  • Renner, O.; Salzmann, D.; Sondhauß, P.
  • Journal of Physics B: Atomic, Molecular and Optical Physics, Vol. 31, Issue 6
  • DOI: 10.1088/0953-4075/31/6/022

Demonstration of aluminum K -shell line shifts in isochorically heated targets driven by ultrashort laser pulses
journal, December 2002


Evidence of plasma polarization shift of Ti He-α resonance line in high density laser produced plasmas
journal, December 2012


Lineshape spectroscopy with a very high resolution, very high signal-to-noise crystal spectrometer
journal, June 2016

  • Beiersdorfer, P.; Magee, E. W.; Brown, G. V.
  • Review of Scientific Instruments, Vol. 87, Issue 6
  • DOI: 10.1063/1.4952748

Comprehensive description of the Orion laser facility
journal, April 2015


Measurements of emission spectra from hot, dense germanium plasma in short pulse laser experiments
journal, January 2010


The first data from the Orion laser; measurements of the spectrum of hot, dense aluminium
journal, December 2013


Modelling K shell spectra from short pulse heated buried microdot targets
journal, June 2017


Lineshape measurements of He- β spectra on the ORION laser facility
journal, October 2016

  • Beiersdorfer, P.; Brown, G. V.; Shepherd, R.
  • Physics of Plasmas, Vol. 23, Issue 10
  • DOI: 10.1063/1.4965233

Imaging crystal spectrometer for high-resolution x-ray measurements on electron beam ion traps and tokamaks
journal, September 2016

  • Beiersdorfer, P.; Magee, E. W.; Hell, N.
  • Review of Scientific Instruments, Vol. 87, Issue 11
  • DOI: 10.1063/1.4962049

Calibration of the OHREX high-resolution imaging crystal spectrometer at the Livermore electron beam ion traps
journal, August 2016

  • Hell, N.; Beiersdorfer, P.; Magee, E. W.
  • Review of Scientific Instruments, Vol. 87, Issue 11
  • DOI: 10.1063/1.4959947

Plasma spectroscopy
journal, January 1966


Stark Broadening of Hydrogen Lines in a Plasma
journal, October 1959

  • Griem, Hans R.; Kolb, Alan C.; Shen, K. Y.
  • Physical Review, Vol. 116, Issue 1
  • DOI: 10.1103/physrev.116.4

Imaging x-ray crystal spectrometers for the National Spherical Torus Experiment
journal, January 1999

  • Bitter, M.; Hill, K. W.; Roquemore, A. L.
  • Review of Scientific Instruments, Vol. 70, Issue 1
  • DOI: 10.1063/1.1149344

The ITER core imaging x-ray spectrometer
journal, July 2010

  • Beiersdorfer, P.; Clementson, J.; Dunn, J.
  • Journal of Physics B: Atomic, Molecular and Optical Physics, Vol. 43, Issue 14
  • DOI: 10.1088/0953-4075/43/14/144008

Spherical quartz crystals investigated with synchrotron radiation
journal, October 2015

  • Pereira, N. R.; Macrander, A. T.; Hill, K. W.
  • Review of Scientific Instruments, Vol. 86, Issue 10
  • DOI: 10.1063/1.4934197