Title: Performance of the Muon $g-2$ Calorimeter and Readout Systems Measured with Test Beam Data

Abstract

A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$$_{2}$$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800 MSPS waveform digitizers, a clock and control distribution network, a gain calibration and monitoring system, and a GPU-based frontend read out through a MIDAS data acquisition environment. The entire system performance was evaluated using 2.5 - 5 GeV electrons at the End Station Test Beam at SLAC. This paper includes a description of the individual subsystems and the results of measurements of the energy response and resolution, energy-scale stability, timing resolution, and spatial uniformity. All measured performances meet or exceed the $g-2$ experimental requirements. Based on the success of the tests, the complete production of the required 24 calorimeter stations has been made and installation into the main experiment is complete. Furthermore, the calorimeter response measurements determined here informed the design of the reconstruction algorithms that are now employed in the running $g-2$ experiment.

Authors:
Publication Date:
Research Org.:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Org.:
USDOE Office of Science (SC), High Energy Physics (HEP) (SC-25)
Contributing Org.:
Muon g-2
OSTI Identifier:
1545084
Report Number(s):
arXiv:1905.04407; FERMILAB-PUB-19-198-PPD
1734415
DOE Contract Number:  
AC02-07CH11359
Resource Type:
Journal Article
Journal Name:
TBD
Additional Journal Information:
Journal Name: TBD
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Citation Formats

Khaw, K. S., and et al. Performance of the Muon $g-2$ Calorimeter and Readout Systems Measured with Test Beam Data. United States: N. p., 2019. Web.
Khaw, K. S., & et al. Performance of the Muon $g-2$ Calorimeter and Readout Systems Measured with Test Beam Data. United States.
Khaw, K. S., and et al. Fri . "Performance of the Muon $g-2$ Calorimeter and Readout Systems Measured with Test Beam Data". United States. https://www.osti.gov/servlets/purl/1545084.
@article{osti_1545084,
title = {Performance of the Muon $g-2$ Calorimeter and Readout Systems Measured with Test Beam Data},
author = {Khaw, K. S. and et al.},
abstractNote = {A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$_{2}$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800 MSPS waveform digitizers, a clock and control distribution network, a gain calibration and monitoring system, and a GPU-based frontend read out through a MIDAS data acquisition environment. The entire system performance was evaluated using 2.5 - 5 GeV electrons at the End Station Test Beam at SLAC. This paper includes a description of the individual subsystems and the results of measurements of the energy response and resolution, energy-scale stability, timing resolution, and spatial uniformity. All measured performances meet or exceed the $g-2$ experimental requirements. Based on the success of the tests, the complete production of the required 24 calorimeter stations has been made and installation into the main experiment is complete. Furthermore, the calorimeter response measurements determined here informed the design of the reconstruction algorithms that are now employed in the running $g-2$ experiment.},
doi = {},
journal = {TBD},
number = ,
volume = ,
place = {United States},
year = {2019},
month = {5}
}