Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector

Journal Article · · Journal of the American Society for Mass Spectrometry
Not provided.
Research Organization:
Duke Univ., Durham, NC (United States)
Sponsoring Organization:
USDOE Advanced Research Projects Agency - Energy (ARPA-E)
DOE Contract Number:
AR0000546;
OSTI ID:
1537866
Journal Information:
Journal of the American Society for Mass Spectrometry, Journal Name: Journal of the American Society for Mass Spectrometry Journal Issue: 2 Vol. 29; ISSN 1044-0305
Publisher:
American Society for Mass Spectrometry
Country of Publication:
United States
Language:
English

References (43)

Mass spectrometric investigation of dissociative ionization of toxic gases by electrons at 20-1000 eV journal October 1988
Design of Portable Mass Spectrometers with Handheld Probes: Aspects of the Sampling and Miniature Pumping Systems journal November 2014
A Field-Portable Membrane Introduction Mass Spectrometer for Real-time Quantitation and Spatial Mapping of Atmospheric and Aqueous Contaminants journal December 2014
Two-Dimensional Aperture Coding for Magnetic Sector Mass Spectrometry journal December 2014
Order of Magnitude Signal Gain in Magnetic Sector Mass Spectrometry Via Aperture Coding journal June 2015
Chemical Ionization Mass Spectrometry Using Carbon Nanotube Field Emission Electron Sources journal July 2015
Compatibility of Spatially Coded Apertures with a Miniature Mattauch-Herzog Mass Spectrograph journal January 2016
Dual collector cycloidal mass spectrometer for precision analysis of hydrogen isotopes journal December 1985
NEREUS: engineering concept for an underwater mass spectrometer journal August 2002
NEREUS/Kemonaut, a mobile autonomous underwater mass spectrometer journal April 2004
A miniature electron ionization source fabricated using microelectromechanical systems (MEMS) with integrated carbon nanotube (CNT) field emission cathodes and low-temperature co-fired ceramics (LTCC) journal November 2017
A portable mass spectrometer study targeting anthropogenic contaminants in Sub-Antarctic Puerto Williams, Chile journal November 2017
Implementation of DART and DESI Ionization on a Fieldable Mass Spectrometer journal October 2008
A MEMS electron impact ion source integrated in a microtime-of-flight mass spectrometer journal December 2013
Monitoring of Toxic Compounds in Air Using a Handheld Rectilinear Ion Trap Mass Spectrometer journal February 2008
Detection of Explosives as Negative Ions Directly from Surfaces Using a Miniature Mass Spectrometer journal June 2010
Carbon Nanotube Electron Ionization Source for Portable Mass Spectrometry journal September 2011
Miniature and Fieldable Mass Spectrometers: Recent Advances journal October 2015
Characterizing Spatial and Temporal Variability of Dissolved Gases in Aquatic Environments with in situ Mass Spectrometry journal July 2009
New ionization methods and miniature mass spectrometers for biomedicine: DESI imaging for cancer diagnostics and paper spray ionization for therapeutic drug monitoring journal January 2011
Evaluation of a fourth-generation focal plane camera for use in plasma-source mass spectrometry journal January 2011
Carbon nanotubes as field emission sources journal January 2004
A backpack‐portable mass spectrometer for measurement of volatile compounds in the environment journal June 1991
Observation of Metastable Ions in a Cycloidal Mass Spectrometer journal May 1968
Small General Purpose Cycloidal‐Focusing Mass Spectrometer journal July 1956
Nonuniform Fields in Cycloidal‐Focusing Mass Spectrometers journal July 1956
Space Charge in Cycloidal‐Focusing Mass Spectrometers journal July 1956
A 40‐Centimeter Trochoidal Type Mass Spectrometer: Trochotron journal October 1947
Trochotron Design Principles journal February 1949
A Large Mass Spectrometer Employing Crossed Electric and Magnetic Fields journal April 1949
On-chip electron-impact ion source using carbon nanotube field emitters journal March 2007
Analysis of 3-panel and 4-panel microscale ionization sources journal June 2010
A compact E × B filter: A multi-collector cycloidal focusing mass spectrometer journal October 2015
An iterative technique for the rectification of observed distributions journal June 1974
A multicollector, cycloidal focusing, magnetic mass spectrometer journal September 1974
An improved detector for a multicollector, cycloidal focusing, magnetic mass spectrometer journal January 1975
A cycloidal mass spectrometer with 100% collection efficiency journal September 1966
A New Mass Spectrometer with Improved Focusing Properties journal April 1938
A Microionizer for Portable Mass Spectrometers Using Double-Gated Isolated Vertically Aligned Carbon Nanofiber Arrays journal July 2011
MEMS-Type Self-Packaged Field-Emission Electron Source journal July 2015
Tracking Hydrocarbon Plume Transport and Biodegradation at Deepwater Horizon journal August 2010
Coded Apertures in Mass Spectrometry journal June 2017
Bayesian-Based Iterative Method of Image Restoration* journal January 1972

Similar Records

Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector
Journal Article · 2018 · Journal of the American Society for Mass Spectrometry · OSTI ID:22776782

Improving the Performance of a Cycloidal Coded-Aperture Miniature Mass Spectrometer
Journal Article · 2020 · Journal of the American Society for Mass Spectrometry · OSTI ID:1848199

Effects of Magnetic and Electric Field Uniformity on Coded Aperture Imaging Quality in a Cycloidal Mass Analyzer
Journal Article · 2017 · Journal of the American Society for Mass Spectrometry · OSTI ID:1537867