Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector

Journal Article · · Journal of the American Society for Mass Spectrometry

Not provided.

Research Organization:
Duke Univ., Durham, NC (United States)
Sponsoring Organization:
USDOE Advanced Research Projects Agency - Energy (ARPA-E)
DOE Contract Number:
AR0000546
OSTI ID:
1537866
Journal Information:
Journal of the American Society for Mass Spectrometry, Vol. 29, Issue 2; ISSN 1044-0305
Publisher:
American Society for Mass Spectrometry
Country of Publication:
United States
Language:
English

References (43)

Miniature and Fieldable Mass Spectrometers: Recent Advances journal October 2015
A portable mass spectrometer study targeting anthropogenic contaminants in Sub-Antarctic Puerto Williams, Chile journal November 2017
A Field-Portable Membrane Introduction Mass Spectrometer for Real-time Quantitation and Spatial Mapping of Atmospheric and Aqueous Contaminants journal December 2014
Tracking Hydrocarbon Plume Transport and Biodegradation at Deepwater Horizon journal August 2010
Monitoring of Toxic Compounds in Air Using a Handheld Rectilinear Ion Trap Mass Spectrometer journal February 2008
Detection of Explosives as Negative Ions Directly from Surfaces Using a Miniature Mass Spectrometer journal June 2010
Design of Portable Mass Spectrometers with Handheld Probes: Aspects of the Sampling and Miniature Pumping Systems journal November 2014
New ionization methods and miniature mass spectrometers for biomedicine: DESI imaging for cancer diagnostics and paper spray ionization for therapeutic drug monitoring journal January 2011
Implementation of DART and DESI Ionization on a Fieldable Mass Spectrometer journal October 2008
Coded Apertures in Mass Spectrometry journal June 2017
Order of Magnitude Signal Gain in Magnetic Sector Mass Spectrometry Via Aperture Coding journal June 2015
Two-Dimensional Aperture Coding for Magnetic Sector Mass Spectrometry journal December 2014
Compatibility of Spatially Coded Apertures with a Miniature Mattauch-Herzog Mass Spectrograph journal January 2016
A New Mass Spectrometer with Improved Focusing Properties journal April 1938
A Large Mass Spectrometer Employing Crossed Electric and Magnetic Fields journal April 1949
A 40‐Centimeter Trochoidal Type Mass Spectrometer: Trochotron journal October 1947
Trochotron Design Principles journal February 1949
Nonuniform Fields in Cycloidal‐Focusing Mass Spectrometers journal July 1956
Space Charge in Cycloidal‐Focusing Mass Spectrometers journal July 1956
Small General Purpose Cycloidal‐Focusing Mass Spectrometer journal July 1956
Observation of Metastable Ions in a Cycloidal Mass Spectrometer journal May 1968
A cycloidal mass spectrometer with 100% collection efficiency journal September 1966
Mass spectrometric investigation of dissociative ionization of toxic gases by electrons at 20-1000 eV journal October 1988
A multicollector, cycloidal focusing, magnetic mass spectrometer journal September 1974
An improved detector for a multicollector, cycloidal focusing, magnetic mass spectrometer journal January 1975
Dual collector cycloidal mass spectrometer for precision analysis of hydrogen isotopes journal December 1985
A backpack‐portable mass spectrometer for measurement of volatile compounds in the environment journal June 1991
NEREUS: engineering concept for an underwater mass spectrometer journal August 2002
NEREUS/Kemonaut, a mobile autonomous underwater mass spectrometer journal April 2004
Characterizing Spatial and Temporal Variability of Dissolved Gases in Aquatic Environments with in situ Mass Spectrometry journal July 2009
A compact E × B filter: A multi-collector cycloidal focusing mass spectrometer journal October 2015
Carbon nanotubes as field emission sources journal January 2004
Chemical Ionization Mass Spectrometry Using Carbon Nanotube Field Emission Electron Sources journal July 2015
Carbon Nanotube Electron Ionization Source for Portable Mass Spectrometry journal September 2011
A Microionizer for Portable Mass Spectrometers Using Double-Gated Isolated Vertically Aligned Carbon Nanofiber Arrays journal July 2011
A MEMS electron impact ion source integrated in a microtime-of-flight mass spectrometer journal December 2013
MEMS-Type Self-Packaged Field-Emission Electron Source journal July 2015
On-chip electron-impact ion source using carbon nanotube field emitters journal March 2007
Analysis of 3-panel and 4-panel microscale ionization sources journal June 2010
A miniature electron ionization source fabricated using microelectromechanical systems (MEMS) with integrated carbon nanotube (CNT) field emission cathodes and low-temperature co-fired ceramics (LTCC) journal November 2017
Evaluation of a fourth-generation focal plane camera for use in plasma-source mass spectrometry journal January 2011
An iterative technique for the rectification of observed distributions journal June 1974
Bayesian-Based Iterative Method of Image Restoration* journal January 1972