skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Enhanced sensitivity and metabolite coverage with remote laser ablation electrospray ionization-mass spectrometry aided by coaxial plume and gas dynamics

Abstract

Conical ablation chamber for remote LAESI-MS exhibits enhanced molecular coverage compared to conventional arrangement.

Authors:
 [1];  [1];  [2];  [2];  [2]; ORCiD logo [1]
  1. Department of Chemistry; The George Washington University; Washington; USA
  2. Protea Biosciences; USA
Publication Date:
Research Org.:
George Washington Univ., Washington, DC (United States); Univ. of Missouri, Columbia, MO (United States)
Sponsoring Org.:
USDOE Office of Science (SC)
OSTI Identifier:
1535173
DOE Contract Number:  
FG02-01ER15129; SC0013978
Resource Type:
Journal Article
Journal Name:
Analyst
Additional Journal Information:
Journal Volume: 142; Journal Issue: 17; Journal ID: ISSN 0003-2654
Publisher:
Royal Society of Chemistry
Country of Publication:
United States
Language:
English
Subject:
Chemistry

Citation Formats

Fincher, Jarod A., Korte, Andrew R., Reschke, Brent, Morris, Nicholas J., Powell, Matthew J., and Vertes, Akos. Enhanced sensitivity and metabolite coverage with remote laser ablation electrospray ionization-mass spectrometry aided by coaxial plume and gas dynamics. United States: N. p., 2017. Web. doi:10.1039/c7an00805h.
Fincher, Jarod A., Korte, Andrew R., Reschke, Brent, Morris, Nicholas J., Powell, Matthew J., & Vertes, Akos. Enhanced sensitivity and metabolite coverage with remote laser ablation electrospray ionization-mass spectrometry aided by coaxial plume and gas dynamics. United States. doi:10.1039/c7an00805h.
Fincher, Jarod A., Korte, Andrew R., Reschke, Brent, Morris, Nicholas J., Powell, Matthew J., and Vertes, Akos. Sun . "Enhanced sensitivity and metabolite coverage with remote laser ablation electrospray ionization-mass spectrometry aided by coaxial plume and gas dynamics". United States. doi:10.1039/c7an00805h.
@article{osti_1535173,
title = {Enhanced sensitivity and metabolite coverage with remote laser ablation electrospray ionization-mass spectrometry aided by coaxial plume and gas dynamics},
author = {Fincher, Jarod A. and Korte, Andrew R. and Reschke, Brent and Morris, Nicholas J. and Powell, Matthew J. and Vertes, Akos},
abstractNote = {Conical ablation chamber for remote LAESI-MS exhibits enhanced molecular coverage compared to conventional arrangement.},
doi = {10.1039/c7an00805h},
journal = {Analyst},
issn = {0003-2654},
number = 17,
volume = 142,
place = {United States},
year = {2017},
month = {1}
}

Works referenced in this record:

Direct, trace level detection of explosives on ambient surfaces by desorption electrospray ionization mass spectrometry
journal, January 2005

  • Takáts, Zoltán; Cotte-Rodriguez, Ismael; Talaty, Nari
  • Chem. Commun., Issue 15
  • DOI: 10.1039/B418697D

Desorption Electrospray Ionization Mass Spectrometry for High-Throughput Analysis of Pharmaceutical Samples in the Ambient Environment
journal, November 2005

  • Chen, Huanwen; Talaty, Nari N.; Takáts, Zoltán
  • Analytical Chemistry, Vol. 77, Issue 21
  • DOI: 10.1021/ac050989d

Forensic applications of ambient ionization mass spectrometry
journal, February 2009

  • Ifa, Demian R.; Jackson, Ayanna U.; Paglia, Giuseppe
  • Analytical and Bioanalytical Chemistry, Vol. 394, Issue 8
  • DOI: 10.1007/s00216-009-2659-2

Ambient Molecular Imaging and Depth Profiling of Live Tissue by Infrared Laser Ablation Electrospray Ionization Mass Spectrometry
journal, June 2008

  • Nemes, Peter; Barton, Alexis A.; Li, Yue
  • Analytical Chemistry, Vol. 80, Issue 12
  • DOI: 10.1021/ac8004082

Ambient mass spectrometry for in vivo local analysis and in situ molecular tissue imaging
journal, April 2012


Ambient desorption ionization mass spectrometry
journal, April 2008

  • Venter, Andre; Nefliu, Marcela; Graham Cooks, R.
  • TrAC Trends in Analytical Chemistry, Vol. 27, Issue 4
  • DOI: 10.1016/j.trac.2008.01.010

Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
journal, October 2004


Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient Conditions
journal, April 2005

  • Cody, Robert B.; Laramée, James A.; Durst, H. Dupont
  • Analytical Chemistry, Vol. 77, Issue 8, p. 2297-2302
  • DOI: 10.1021/ac050162j

Laser Ablation Electrospray Ionization for Atmospheric Pressure, in Vivo, and Imaging Mass Spectrometry
journal, November 2007

  • Nemes, Peter; Vertes, Akos
  • Analytical Chemistry, Vol. 79, Issue 21
  • DOI: 10.1021/ac071181r

In vivo Real-Time Mass Spectrometry for Guided Surgery Application
journal, May 2016

  • Fatou, Benoit; Saudemont, Philippe; Leblanc, Eric
  • Scientific Reports, Vol. 6, Issue 1
  • DOI: 10.1038/srep25919

Rapid Evaporative Ionization Mass Spectrometry Imaging Platform for Direct Mapping from Bulk Tissue and Bacterial Growth Media
journal, February 2015

  • Golf, Ottmar; Strittmatter, Nicole; Karancsi, Tamas
  • Analytical Chemistry, Vol. 87, Issue 5
  • DOI: 10.1021/ac5046752

Intraoperative Tissue Identification Using Rapid Evaporative Ionization Mass Spectrometry
journal, July 2013


Study of the efficiency for ion transfer through bent capillaries: Ion transfer through bent capillaries
journal, October 2012

  • Chen, Tsung-Chi; Xu, Wei; Garimella, Sandilya
  • Journal of Mass Spectrometry, Vol. 47, Issue 11
  • DOI: 10.1002/jms.3117

Gas-flow assisted ion transfer for mass spectrometry: Flow assisted ion transfer
journal, February 2012

  • Garimella, Sandilya; Xu, Wei; Huang, Guangming
  • Journal of Mass Spectrometry, Vol. 47, Issue 2, p. 201-207
  • DOI: 10.1002/jms.2955

Real-Time Sample Analysis Using a Sampling Probe and Miniature Mass Spectrometer
journal, August 2015


Aerodynamic focusing of particles in a carrier gas
journal, October 1988


Remote mass spectrometric sampling of electrospray- and desorption electrospray-generated ions using an air ejector
journal, October 2007

  • Dixon, R. Brent; Bereman, Michael S.; Muddiman, David C.
  • Journal of the American Society for Mass Spectrometry, Vol. 18, Issue 10
  • DOI: 10.1016/j.jasms.2007.07.024

Analyte response in laser ablation inductively coupled plasma mass spectrometry
journal, May 2006

  • Wang, Zhongke; Hattendorf, Bodo; Günther, Detlef
  • Journal of the American Society for Mass Spectrometry, Vol. 17, Issue 5
  • DOI: 10.1016/j.jasms.2006.01.005

Effects of Particle Size Distribution on Inductively Coupled Plasma Mass Spectrometry Signal Intensity during Laser Ablation of Glass Samples
journal, November 1999

  • Jeong, S. H.; Borisov, O. V.; Yoo, J. H.
  • Analytical Chemistry, Vol. 71, Issue 22
  • DOI: 10.1021/ac990455a

Laser microdissection and atmospheric pressure chemical ionization mass spectrometry coupled for multimodal imaging: LA-APCI/MS imaging
journal, May 2013

  • Lorenz, Matthias; Ovchinnikova, Olga S.; Kertesz, Vilmos
  • Rapid Communications in Mass Spectrometry, Vol. 27, Issue 13
  • DOI: 10.1002/rcm.6593

Ambient laser ablation sampling for capillary electrophoresis mass spectrometry: Ambient laser ablation sampling for CE/MS
journal, June 2013

  • Park, Sung-Gun; Murray, Kermit K.
  • Rapid Communications in Mass Spectrometry, Vol. 27, Issue 15
  • DOI: 10.1002/rcm.6618

Remote laser ablation electrospray ionization mass spectrometry for non-proximate analysis of biological tissues: Non-proximate analysis of biological tissues by LAESI-MS
journal, December 2014

  • Compton, Laine R.; Reschke, Brent; Friend, Jordan
  • Rapid Communications in Mass Spectrometry, Vol. 29, Issue 1
  • DOI: 10.1002/rcm.7077

Plasticizers, antioxidants, and other contaminants found in air delivered by PVC tubing used in respiratory therapy
journal, January 2003

  • Hill, Sandra S.; Shaw, Brenda R.; Wu, Alan H. B.
  • Biomedical Chromatography, Vol. 17, Issue 4
  • DOI: 10.1002/bmc.231

In Situ Analysis of Small Populations of Adherent Mammalian Cells Using Laser Ablation Electrospray Ionization Mass Spectrometry in Transmission Geometry
journal, November 2015


Drag Coefficients of Spheres in Continuum and Rarefied Flows
journal, June 1976

  • Henderson, Charles B.
  • AIAA Journal, Vol. 14, Issue 6
  • DOI: 10.2514/3.61409

Material ejection in nanosecond Er:YAG laser ablation of water, liver, and skin
journal, July 2005


Internal energy deposition and ion fragmentation in atmospheric-pressure mid-infrared laser ablation electrospray ionization
journal, January 2012

  • Nemes, Peter; Huang, Hehua; Vertes, Akos
  • Physical Chemistry Chemical Physics, Vol. 14, Issue 7
  • DOI: 10.1039/c2cp23411d

Particle size measurement from infrared laser ablation of tissue
journal, January 2016

  • Cao, Fan; Donnarumma, Fabrizio; Murray, Kermit K.
  • The Analyst, Vol. 141, Issue 1
  • DOI: 10.1039/C5AN01765C

Glucosinolates in Brassica vegetables: The influence of the food supply chain on intake, bioavailability and human health
journal, November 2008

  • Verkerk, Ruud; Schreiner, Monika; Krumbein, Angelika
  • Molecular Nutrition & Food Research, Vol. 53, Issue S2
  • DOI: 10.1002/mnfr.200800065

The chemical diversity and distribution of glucosinolates and isothiocyanates among plants
journal, January 2001


mMass 3: A Cross-Platform Software Environment for Precise Analysis of Mass Spectrometric Data
journal, June 2010

  • Strohalm, Martin; Kavan, Daniel; Novák, Petr
  • Analytical Chemistry, Vol. 82, Issue 11
  • DOI: 10.1021/ac100818g

Analysis of glucosinolates, isothiocyanates, and amine degradation products in vegetable extracts and blood plasma by LC–MS/MS
journal, December 2005

  • Song, Lijiang; Morrison, John J.; Botting, Nigel P.
  • Analytical Biochemistry, Vol. 347, Issue 2
  • DOI: 10.1016/j.ab.2005.09.040