Ultrasonic Examination of Double-Shell Tank 241-AZ-102 Examination Completed August 2003
Abstract
COGEMA Engineering Corporation (COGEMA), under a contract from CH2M Hill Hanford Group (CH2M Hill), has performed an ultrasonic nondestructive examination of selected portions of Double-Shell Tank 241-AZ-102. The purpose of this examination was to provide information that could be used to evaluate the integrity of the wall of the primary tank. The requirements for the ultrasonic examination of Tank 241-AZ-102 were to detect, characterize (identify, size, and locate), and record measurements made of any wall thinning, pitting, or cracks that might be present in the wall of the primary tank. Any measurements that exceed the requirements set forth in the Engineering Task Plat (ETP), RPP-11832 (Jensen 2002) and summarized on page 1 of this document, are reported to CH2M Hill and the Pacific Northwest National Laboratory (PNNL) for further evaluation. Under the contract with CH2M Hill, all data is to be recorded on disk and paper copies of all measurements are provided to PNNL for third-party evaluation. PNNL is responsible for preparing a report that describes the results of the COGEMA ultrasonic examinations.
- Authors:
- Publication Date:
- Research Org.:
- Pacific Northwest National Lab., Richland, WA (US)
- Sponsoring Org.:
- US Department of Energy (US)
- OSTI Identifier:
- 15010542
- Report Number(s):
- PNNL-14373 Rev.0
820201000; TRN: US0500245
- DOE Contract Number:
- AC05-76RL01830
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: PBD: 1 Sep 2003
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 12 MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; STORAGE FACILITIES; HANFORD RESERVATION; ULTRASONIC TESTING; WALLS; DST; UT; 241-AZ-102; PNNL; ULTRASONIC
Citation Formats
Pardini, Allan F, and Posakony, Gerald J. Ultrasonic Examination of Double-Shell Tank 241-AZ-102 Examination Completed August 2003. United States: N. p., 2003.
Web. doi:10.2172/15010542.
Pardini, Allan F, & Posakony, Gerald J. Ultrasonic Examination of Double-Shell Tank 241-AZ-102 Examination Completed August 2003. United States. https://doi.org/10.2172/15010542
Pardini, Allan F, and Posakony, Gerald J. Mon .
"Ultrasonic Examination of Double-Shell Tank 241-AZ-102 Examination Completed August 2003". United States. https://doi.org/10.2172/15010542. https://www.osti.gov/servlets/purl/15010542.
@article{osti_15010542,
title = {Ultrasonic Examination of Double-Shell Tank 241-AZ-102 Examination Completed August 2003},
author = {Pardini, Allan F and Posakony, Gerald J},
abstractNote = {COGEMA Engineering Corporation (COGEMA), under a contract from CH2M Hill Hanford Group (CH2M Hill), has performed an ultrasonic nondestructive examination of selected portions of Double-Shell Tank 241-AZ-102. The purpose of this examination was to provide information that could be used to evaluate the integrity of the wall of the primary tank. The requirements for the ultrasonic examination of Tank 241-AZ-102 were to detect, characterize (identify, size, and locate), and record measurements made of any wall thinning, pitting, or cracks that might be present in the wall of the primary tank. Any measurements that exceed the requirements set forth in the Engineering Task Plat (ETP), RPP-11832 (Jensen 2002) and summarized on page 1 of this document, are reported to CH2M Hill and the Pacific Northwest National Laboratory (PNNL) for further evaluation. Under the contract with CH2M Hill, all data is to be recorded on disk and paper copies of all measurements are provided to PNNL for third-party evaluation. PNNL is responsible for preparing a report that describes the results of the COGEMA ultrasonic examinations.},
doi = {10.2172/15010542},
url = {https://www.osti.gov/biblio/15010542},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2003},
month = {9}
}