Title: Results of Performance Evaluation Testing of Electrical Leak-Detection Methods at the Hanford Mock Tank Site--FY 2002-2003

Technical Report ·
DOI:https://doi.org/10.2172/15010193· OSTI ID:15010193

Application of two electrical resistivity methods at the Hanford Site Mock Tank during 2002, indicate the viability of the methods as possible leak-detection tools for SST retrieval operations. Electrical Resistivity Tomography and High-Resolution Resistivity were used over a 109-day period to detect leakage of a waste simulant beneath the tank. The results of the test indicate that both of these two methods, and subset methods may be applicable to SST leak detection.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
15010193
Report Number(s):
PNNL-14192; 820201000; TRN: US0500219
Country of Publication:
United States
Language:
English