skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Comparison of Response Characteristics of High-Purity Germanium Detectors using Analog Versus Digital Processing

Abstract

In this article we will discuss some of the results of the response characteristics of High Purity germanium detectors using analog versus digital processing of the signals that are outputted from the detector. The discussion will focus on whether or not there is a significant difference in the response of the detector with digital electronics that it limits the ability of the detection system to get reasonable gamma ray spectrometric results. Particularly, whether or not the performance of the analysis code Pu600 is compromised.

Authors:
;
Publication Date:
Research Org.:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Org.:
US Department of Energy (US)
OSTI Identifier:
15009837
Report Number(s):
UCRL-TR-203778
TRN: US0406644
DOE Contract Number:  
W-7405-ENG-48
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 23 Apr 2004
Country of Publication:
United States
Language:
English
Subject:
73 NUCLEAR PHYSICS AND RADIATION PHYSICS; DETECTION; GE SEMICONDUCTOR DETECTORS; PERFORMANCE; PROCESSING

Citation Formats

Luke, S J, and Raschke, K. Comparison of Response Characteristics of High-Purity Germanium Detectors using Analog Versus Digital Processing. United States: N. p., 2004. Web. doi:10.2172/15009837.
Luke, S J, & Raschke, K. Comparison of Response Characteristics of High-Purity Germanium Detectors using Analog Versus Digital Processing. United States. https://doi.org/10.2172/15009837
Luke, S J, and Raschke, K. Fri . "Comparison of Response Characteristics of High-Purity Germanium Detectors using Analog Versus Digital Processing". United States. https://doi.org/10.2172/15009837. https://www.osti.gov/servlets/purl/15009837.
@article{osti_15009837,
title = {Comparison of Response Characteristics of High-Purity Germanium Detectors using Analog Versus Digital Processing},
author = {Luke, S J and Raschke, K},
abstractNote = {In this article we will discuss some of the results of the response characteristics of High Purity germanium detectors using analog versus digital processing of the signals that are outputted from the detector. The discussion will focus on whether or not there is a significant difference in the response of the detector with digital electronics that it limits the ability of the detection system to get reasonable gamma ray spectrometric results. Particularly, whether or not the performance of the analysis code Pu600 is compromised.},
doi = {10.2172/15009837},
url = {https://www.osti.gov/biblio/15009837}, journal = {},
number = ,
volume = ,
place = {United States},
year = {2004},
month = {4}
}