skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: The raw disk i/o performance of compaq storage works RAID arrays under tru64 unix

Abstract

We report on the raw disk i/o performance of a set of Compaq StorageWorks RAID arrays connected to our cluster of Compaq ES40 computers via Fibre Channel. The best cumulative peak sustained data rate is l17MB/s per node for reads and 77MB/s per node for writes. This value occurs for a configuration in which a node has two Fibre Channel interfaces to a switch, which in turn has two connections to each of two Compaq StorageWorks RAID arrays. Each RAID array has two HSG80 RAID controllers controlling (together) two 5+p RAID chains. A 10% more space efficient arrangement using a single 1l+p RAID chain in place of the two 5+P chains is 25% slower for reads and 40% slower for writes.

Authors:
Publication Date:
Research Org.:
Lawrence Livermore National Lab., CA (US)
Sponsoring Org.:
US Department of Energy (US)
OSTI Identifier:
15006441
Report Number(s):
UCRL-ID-141831
TRN: US200411%%79
DOE Contract Number:
W-7405-ENG-48
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 19 Oct 2000
Country of Publication:
United States
Language:
English
Subject:
99 GENERAL AND MISCELLANEOUS//MATHEMATICS, COMPUTING, AND INFORMATION SCIENCE; COMPUTERS; CONFIGURATION; PERFORMANCE; STORAGE

Citation Formats

Uselton, A C. The raw disk i/o performance of compaq storage works RAID arrays under tru64 unix. United States: N. p., 2000. Web. doi:10.2172/15006441.
Uselton, A C. The raw disk i/o performance of compaq storage works RAID arrays under tru64 unix. United States. doi:10.2172/15006441.
Uselton, A C. Thu . "The raw disk i/o performance of compaq storage works RAID arrays under tru64 unix". United States. doi:10.2172/15006441. https://www.osti.gov/servlets/purl/15006441.
@article{osti_15006441,
title = {The raw disk i/o performance of compaq storage works RAID arrays under tru64 unix},
author = {Uselton, A C},
abstractNote = {We report on the raw disk i/o performance of a set of Compaq StorageWorks RAID arrays connected to our cluster of Compaq ES40 computers via Fibre Channel. The best cumulative peak sustained data rate is l17MB/s per node for reads and 77MB/s per node for writes. This value occurs for a configuration in which a node has two Fibre Channel interfaces to a switch, which in turn has two connections to each of two Compaq StorageWorks RAID arrays. Each RAID array has two HSG80 RAID controllers controlling (together) two 5+p RAID chains. A 10% more space efficient arrangement using a single 1l+p RAID chain in place of the two 5+P chains is 25% slower for reads and 40% slower for writes.},
doi = {10.2172/15006441},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Oct 19 00:00:00 EDT 2000},
month = {Thu Oct 19 00:00:00 EDT 2000}
}

Technical Report:

Save / Share: