Title: Fluorescence intensity monitors as intensity and beam-position diagnostics for X-ray free-electron lasers

Abstract

For LCLS-II, a fluorescence intensity monitor for the non-invasive, pulse-by-pulse normalization of experiments has been developed. A prototype diagnostic was constructed with a microchannel plate assembly and two photodiodes. The diagnostic was then installed in the LCLS SXR instrument Kirkpatrick–Baez mirror chamber with the detectors located above the vertically reflecting mirror. The linearity, noise and position sensitivity of the detectors have been characterized. The photodiode responsivity is suitable for high pulse energies. The microchannel plate detector shows sufficient responsivity over a wide range of pulse energies. The relative signal from the two photodiodes provides a sensitive measure of the X-ray beam position. The fluorescence intensity monitor provides intensity normalization while being compatible with high incident power, a 0.93 MHz repetition rate and ultra-high vacuum.

Authors:
Publication Date:
Research Org.:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Org.:
USDOE Office of Science (SC)
OSTI Identifier:
1496063
DOE Contract Number:  
AC02-76SF00515
Resource Type:
Program Document
Country of Publication:
United States
Language:
English

Citation Formats

Heimann, Philip. Fluorescence intensity monitors as intensity and beam-position diagnostics for X-ray free-electron lasers. United States: N. p., 2019. Web.
Heimann, Philip. Fluorescence intensity monitors as intensity and beam-position diagnostics for X-ray free-electron lasers. United States.
Heimann, Philip. Tue . "Fluorescence intensity monitors as intensity and beam-position diagnostics for X-ray free-electron lasers". United States. https://www.osti.gov/servlets/purl/1496063.
@article{osti_1496063,
title = {Fluorescence intensity monitors as intensity and beam-position diagnostics for X-ray free-electron lasers},
author = {Heimann, Philip},
abstractNote = {For LCLS-II, a fluorescence intensity monitor for the non-invasive, pulse-by-pulse normalization of experiments has been developed. A prototype diagnostic was constructed with a microchannel plate assembly and two photodiodes. The diagnostic was then installed in the LCLS SXR instrument Kirkpatrick–Baez mirror chamber with the detectors located above the vertically reflecting mirror. The linearity, noise and position sensitivity of the detectors have been characterized. The photodiode responsivity is suitable for high pulse energies. The microchannel plate detector shows sufficient responsivity over a wide range of pulse energies. The relative signal from the two photodiodes provides a sensitive measure of the X-ray beam position. The fluorescence intensity monitor provides intensity normalization while being compatible with high incident power, a 0.93 MHz repetition rate and ultra-high vacuum.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2019},
month = {1}
}

Program Document:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item.

Save / Share: