skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Beamline HXN (03-ID, IVU 20): 25 mA Commissioning Radiation Survey Report

Abstract

A comprehensive radiological survey of the Beamline HXN (03-ID, In-Vacuum Undulator) was conducted on February 27 and March 9, 2015 in accordance with the Beamline HXN (03-ID) Radiation Survey Plan [1]. The purpose of the survey is to verify the shielding integrity of the three, 03-ID beamline enclosures (03-ID-A, 03-ID-B, and 03-ID-C) and transport pipes between 03-ID-A and 03-ID-B, and between 03-ID-B and 03-ID-C. During the surveys the stored beam current varied between 20.75 and 23.15 mA,the ID-03 straight section vacuum was approximately 0.76 ntorr, and front-end slits were open near their hard stop limits.

Authors:
 [1];  [1];  [1];  [1]
  1. Brookhaven National Lab. (BNL), Upton, NY (United States)
Publication Date:
Research Org.:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Org.:
USDOE Office of Science (SC), Basic Energy Sciences (BES) (SC-22)
OSTI Identifier:
1493233
Report Number(s):
NSLSII-ESH-TN-174; BNL-210988-2019-TECH
DOE Contract Number:  
SC0012704
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
36 MATERIALS SCIENCE

Citation Formats

Benmerrouche, Mo, Chu, Y., Lee, R., and Zafonte, F. Beamline HXN (03-ID, IVU 20): 25 mA Commissioning Radiation Survey Report. United States: N. p., 2015. Web. doi:10.2172/1493233.
Benmerrouche, Mo, Chu, Y., Lee, R., & Zafonte, F. Beamline HXN (03-ID, IVU 20): 25 mA Commissioning Radiation Survey Report. United States. doi:10.2172/1493233.
Benmerrouche, Mo, Chu, Y., Lee, R., and Zafonte, F. Mon . "Beamline HXN (03-ID, IVU 20): 25 mA Commissioning Radiation Survey Report". United States. doi:10.2172/1493233. https://www.osti.gov/servlets/purl/1493233.
@article{osti_1493233,
title = {Beamline HXN (03-ID, IVU 20): 25 mA Commissioning Radiation Survey Report},
author = {Benmerrouche, Mo and Chu, Y. and Lee, R. and Zafonte, F.},
abstractNote = {A comprehensive radiological survey of the Beamline HXN (03-ID, In-Vacuum Undulator) was conducted on February 27 and March 9, 2015 in accordance with the Beamline HXN (03-ID) Radiation Survey Plan [1]. The purpose of the survey is to verify the shielding integrity of the three, 03-ID beamline enclosures (03-ID-A, 03-ID-B, and 03-ID-C) and transport pipes between 03-ID-A and 03-ID-B, and between 03-ID-B and 03-ID-C. During the surveys the stored beam current varied between 20.75 and 23.15 mA,the ID-03 straight section vacuum was approximately 0.76 ntorr, and front-end slits were open near their hard stop limits.},
doi = {10.2172/1493233},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2015},
month = {5}
}