Title: Radiological Consequences of Beam Loss on Beamline Front End Collimator during Top-off Injection into the Storage Ring

Abstract

The primary radiological safety concern for the top-off injection, with the beam line front end safety shutters open, is the scenario where electrons could be conveyed down to the beam line through the front end due to the erroneous combination of lattice magnetic field settings and beam energy. It is of paramount importance to ensure that such events are of remote possibility. Particle tracking simulations by the NSLS-II Accelerator Physicists have shown that by a set of interlocking requirements of the lattice magnetic fields and by the implementation of physical apertures, the errant electron beam can be confined to the front end components within the storage ring.

Authors:
 [1];  [1];  [1]
  1. Brookhaven National Lab. (BNL), Upton, NY (United States)
Publication Date:
Research Org.:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Org.:
USDOE Office of Science (SC), Basic Energy Sciences (BES) (SC-22)
OSTI Identifier:
1493224
Report Number(s):
NSLSII-ESH-TN-148; BNL-210979-2019-TECH
DOE Contract Number:  
SC0012704
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
36 MATERIALS SCIENCE

Citation Formats

Job, P. K., Popescu, R., and Xia, Z. Radiological Consequences of Beam Loss on Beamline Front End Collimator during Top-off Injection into the Storage Ring. United States: N. p., 2014. Web. doi:10.2172/1493224.
Job, P. K., Popescu, R., & Xia, Z. Radiological Consequences of Beam Loss on Beamline Front End Collimator during Top-off Injection into the Storage Ring. United States. doi:10.2172/1493224.
Job, P. K., Popescu, R., and Xia, Z. Mon . "Radiological Consequences of Beam Loss on Beamline Front End Collimator during Top-off Injection into the Storage Ring". United States. doi:10.2172/1493224. https://www.osti.gov/servlets/purl/1493224.
@article{osti_1493224,
title = {Radiological Consequences of Beam Loss on Beamline Front End Collimator during Top-off Injection into the Storage Ring},
author = {Job, P. K. and Popescu, R. and Xia, Z.},
abstractNote = {The primary radiological safety concern for the top-off injection, with the beam line front end safety shutters open, is the scenario where electrons could be conveyed down to the beam line through the front end due to the erroneous combination of lattice magnetic field settings and beam energy. It is of paramount importance to ensure that such events are of remote possibility. Particle tracking simulations by the NSLS-II Accelerator Physicists have shown that by a set of interlocking requirements of the lattice magnetic fields and by the implementation of physical apertures, the errant electron beam can be confined to the front end components within the storage ring.},
doi = {10.2172/1493224},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2014},
month = {9}
}