Title: Hydrogen Sensor for Parabolic Trough Expansion Tanks

Abstract

The National Renewable Energy Laboratory and Acciona Energy North America are developing and implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. We are pursuing a method that selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid. As part of this effort, we are developing a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. During previous work, we demonstrated that our sensor design measures hydrogen levels over a wide partial pressure range from 1.33 mbar down to 0.003 mbar with an accuracy of +/-20%. We acquired these results under limited conditions because we measured hydrogen partial pressure in gas mixtures of hydrogen and nitrogen only. In this paper, we report our most recent results in which we measured hydrogen partial pressures in gas mixtures that contain hydrogen, nitrogen, biphenyl, and diphenylether. Our results for this gas mixture were essentially the same as those obtained for the hydrogen/nitrogen mixture only, and they also had the same accuracy of +/-20%. This level of accuracy is sufficient to evaluate the performance of a hydrogen mitigation process because hydrogen partial pressure in the expansionmore » tank decreases more than an order of magnitude when the mitigation process is operating. We examined the palladium/silver membrane after completing these measurements and did not observe any signs of membrane deterioration or contamination due to exposure to biphenyl and diphenylether at 405 degrees C. The membrane for these tests was 25 um thick. For the next sensor design that we are developing in 2018, we are using a membrane that is 127 um thick. This thickness is required for the membrane to withstand the 150 psi pressure drop across the membrane when exposed to actual headspace gas from the expansion tank. We performed initial tests in which we exposed a 127-um-thick palladium alloy membrane to 400 degrees C and 150 psi pressure drop and observed no signs of failure or gas leakage. Finally, we developed a transient model that accounts for hydrogen transport mechanisms within the sensor when measurements are made. Our model accounted for hydrogen diffusion through the boundary layer that is adjacent to the membrane and for hydrogen permeation across the membrane and into the permeate volume. Our modeling results agreed very closely with our experimental data when we assumed a boundary-layer thickness of 0.2 cm. This thickness is within the range of expected thicknesses for this gas composition, temperature, and pressure at minimum flowrate. Our model results showed that hydrogen diffusion through the boundary layer adjacent to the membrane is the rate-determining step for the transient pressure response when measuring hydrogen partial pressure.« less

Authors:
 [1]
  1. National Renewable Energy Laboratory (NREL), Golden, CO (United States)
Publication Date:
Research Org.:
National Renewable Energy Lab. (NREL), Golden, CO (United States)
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Solar Energy Technologies Office (EE-4S)
OSTI Identifier:
1485549
Report Number(s):
NREL/CP-5500-68874
DOE Contract Number:  
AC36-08GO28308
Resource Type:
Conference
Resource Relation:
Conference: Presented at SolarPACES 2017: International Conference on Concentrating Solar Power and Chemical Energy Systems, 26-29 September 2017, Santiago, Chile
Country of Publication:
United States
Language:
English
Subject:
14 SOLAR ENERGY; 47 OTHER INSTRUMENTATION; solar; CSP; Acciona; heat transfer fluid

Citation Formats

Glatzmaier, Gregory C. Hydrogen Sensor for Parabolic Trough Expansion Tanks. United States: N. p., 2018. Web. doi:10.1063/1.5067022.
Glatzmaier, Gregory C. Hydrogen Sensor for Parabolic Trough Expansion Tanks. United States. doi:10.1063/1.5067022.
Glatzmaier, Gregory C. Thu . "Hydrogen Sensor for Parabolic Trough Expansion Tanks". United States. doi:10.1063/1.5067022.
@article{osti_1485549,
title = {Hydrogen Sensor for Parabolic Trough Expansion Tanks},
author = {Glatzmaier, Gregory C},
abstractNote = {The National Renewable Energy Laboratory and Acciona Energy North America are developing and implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. We are pursuing a method that selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid. As part of this effort, we are developing a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. During previous work, we demonstrated that our sensor design measures hydrogen levels over a wide partial pressure range from 1.33 mbar down to 0.003 mbar with an accuracy of +/-20%. We acquired these results under limited conditions because we measured hydrogen partial pressure in gas mixtures of hydrogen and nitrogen only. In this paper, we report our most recent results in which we measured hydrogen partial pressures in gas mixtures that contain hydrogen, nitrogen, biphenyl, and diphenylether. Our results for this gas mixture were essentially the same as those obtained for the hydrogen/nitrogen mixture only, and they also had the same accuracy of +/-20%. This level of accuracy is sufficient to evaluate the performance of a hydrogen mitigation process because hydrogen partial pressure in the expansion tank decreases more than an order of magnitude when the mitigation process is operating. We examined the palladium/silver membrane after completing these measurements and did not observe any signs of membrane deterioration or contamination due to exposure to biphenyl and diphenylether at 405 degrees C. The membrane for these tests was 25 um thick. For the next sensor design that we are developing in 2018, we are using a membrane that is 127 um thick. This thickness is required for the membrane to withstand the 150 psi pressure drop across the membrane when exposed to actual headspace gas from the expansion tank. We performed initial tests in which we exposed a 127-um-thick palladium alloy membrane to 400 degrees C and 150 psi pressure drop and observed no signs of failure or gas leakage. Finally, we developed a transient model that accounts for hydrogen transport mechanisms within the sensor when measurements are made. Our model accounted for hydrogen diffusion through the boundary layer that is adjacent to the membrane and for hydrogen permeation across the membrane and into the permeate volume. Our modeling results agreed very closely with our experimental data when we assumed a boundary-layer thickness of 0.2 cm. This thickness is within the range of expected thicknesses for this gas composition, temperature, and pressure at minimum flowrate. Our model results showed that hydrogen diffusion through the boundary layer adjacent to the membrane is the rate-determining step for the transient pressure response when measuring hydrogen partial pressure.},
doi = {10.1063/1.5067022},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2018},
month = {11}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: