skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Complete validation of a continuous and blood-correlated sweat biosensing device with integrated sweat stimulation

Abstract

A wearable sweat biosensing device is demonstrated that stimulates sweat and continuously measures sweat ethanol concentrations at 25 s intervals, which is then correlated with blood ethanol during a >3 hour testing phase.

Authors:
ORCiD logo [1]; ORCiD logo [1];  [2];  [2];  [3];  [3]; ORCiD logo [1];  [4]; ORCiD logo [1];  [1]
  1. Novel Devices Laboratory, College of Engineering, University of Cincinnati, Cincinnati, USA
  2. Biomedical Optics and Sensing Laboratory, Department of Bioengineering, University of Toledo, Toledo, USA
  3. College of Medicine, University of Cincinnati, Cincinnati, USA
  4. UES, Inc., Dayton, USA
Publication Date:
Sponsoring Org.:
USDOE
OSTI Identifier:
1482408
Resource Type:
Journal Article: Publisher's Accepted Manuscript
Journal Name:
Lab on a Chip
Additional Journal Information:
Journal Name: Lab on a Chip Journal Volume: 18 Journal Issue: 24; Journal ID: ISSN 1473-0197
Publisher:
Royal Society of Chemistry (RSC)
Country of Publication:
France
Language:
English

Citation Formats

Hauke, A., Simmers, P., Ojha, Y. R., Cameron, B. D., Ballweg, R., Zhang, T., Twine, N., Brothers, M., Gomez, E., and Heikenfeld, J.. Complete validation of a continuous and blood-correlated sweat biosensing device with integrated sweat stimulation. France: N. p., 2018. Web. doi:10.1039/C8LC01082J.
Hauke, A., Simmers, P., Ojha, Y. R., Cameron, B. D., Ballweg, R., Zhang, T., Twine, N., Brothers, M., Gomez, E., & Heikenfeld, J.. Complete validation of a continuous and blood-correlated sweat biosensing device with integrated sweat stimulation. France. doi:10.1039/C8LC01082J.
Hauke, A., Simmers, P., Ojha, Y. R., Cameron, B. D., Ballweg, R., Zhang, T., Twine, N., Brothers, M., Gomez, E., and Heikenfeld, J.. Tue . "Complete validation of a continuous and blood-correlated sweat biosensing device with integrated sweat stimulation". France. doi:10.1039/C8LC01082J.
@article{osti_1482408,
title = {Complete validation of a continuous and blood-correlated sweat biosensing device with integrated sweat stimulation},
author = {Hauke, A. and Simmers, P. and Ojha, Y. R. and Cameron, B. D. and Ballweg, R. and Zhang, T. and Twine, N. and Brothers, M. and Gomez, E. and Heikenfeld, J.},
abstractNote = {A wearable sweat biosensing device is demonstrated that stimulates sweat and continuously measures sweat ethanol concentrations at 25 s intervals, which is then correlated with blood ethanol during a >3 hour testing phase.},
doi = {10.1039/C8LC01082J},
journal = {Lab on a Chip},
number = 24,
volume = 18,
place = {France},
year = {Tue Dec 04 00:00:00 EST 2018},
month = {Tue Dec 04 00:00:00 EST 2018}
}

Journal Article:
Free Publicly Available Full Text
This content will become publicly available on November 2, 2019
Publisher's Accepted Manuscript

Save / Share:

Works referenced in this record:

Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
journal, July 2013

  • Jia, Wenzhao; Bandodkar, Amay J.; Vald�s-Ram�rez, Gabriela
  • Analytical Chemistry, Vol. 85, Issue 14, p. 6553-6560
  • DOI: 10.1021/ac401573r