November 2016 HERMES Outdoor Shot Series 10268-313: Free Space Fields and Current Coupling
- Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
During the trials during November 2016 at the HERMES III facility, a number of sensors were fielded to measure the free fields and currents coupled to aerial and buried cables. Here, we report on the work done to compensate, correct, and analyze these signals. Average results are presented for selected sets of sensors and preliminary analyses are provided of the time and frequency domain signals. Electric fields were typically on the order of 10 kV/m, magnetic fields were approximately 10 AT, and currents were around 10 A. Several opportunities for improvement are identified including quantification of radiation effects on sensors, higher accuracy compensation techniques, increased sensitivity in differential sensor measurements, and exploration of the use of I-dots in conductivity calculations.
- Research Organization:
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation
- DOE Contract Number:
- AC04-94AL85000; NA0003525
- OSTI ID:
- 1481505
- Report Number(s):
- SAND-2018-12573; 668740
- Country of Publication:
- United States
- Language:
- English
Similar Records
November 2016 HERMES Outdoor Shot Series 10268-313: Courtyard Dosimetry and Parametric Fits
HERMES Outdoor Shot Series 10268- 313: Data Analysis as a Model for Output Voltage and Current Estimates for HERMES Shots; a User Perspective.