Title: Enhanced Component Performance Study: Motor-Driven Pumps 1998–2016

Abstract

This report presents an enhanced performance evaluation of motor-driven pumps (MDP) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2016 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The motor-driven pump failure modes considered for standby systems are failure to start, failure to run less than or equal to one hour, and failure to run more than one hour; for normally running systems, the failure modes considered are failure to start and failure to run. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Highly statistically significant increasing trend was identified in normally running MDP run hours per reactor year.

Authors:
 [1];  [1]
  1. Idaho National Lab. (INL), Idaho Falls, ID (United States)
Publication Date:
Research Org.:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Org.:
USDOE Office of Nuclear Energy (NE)
OSTI Identifier:
1467108
Report Number(s):
INL/EXT-18-44363; NRC-HQ-14-D-0018
TRN: US1901607
DOE Contract Number:  
AC07-05ID14517
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; Motor-Driven Pump; Component Performance; Nuclear Power Plant; Reliability; Trend

Citation Formats

Ma, Zhegang, and Schroeder, John A. Enhanced Component Performance Study: Motor-Driven Pumps 1998–2016. United States: N. p., 2018. Web. doi:10.2172/1467108.
Ma, Zhegang, & Schroeder, John A. Enhanced Component Performance Study: Motor-Driven Pumps 1998–2016. United States. doi:10.2172/1467108.
Ma, Zhegang, and Schroeder, John A. Sun . "Enhanced Component Performance Study: Motor-Driven Pumps 1998–2016". United States. doi:10.2172/1467108. https://www.osti.gov/servlets/purl/1467108.
@article{osti_1467108,
title = {Enhanced Component Performance Study: Motor-Driven Pumps 1998–2016},
author = {Ma, Zhegang and Schroeder, John A.},
abstractNote = {This report presents an enhanced performance evaluation of motor-driven pumps (MDP) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2016 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The motor-driven pump failure modes considered for standby systems are failure to start, failure to run less than or equal to one hour, and failure to run more than one hour; for normally running systems, the failure modes considered are failure to start and failure to run. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Highly statistically significant increasing trend was identified in normally running MDP run hours per reactor year.},
doi = {10.2172/1467108},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2018},
month = {4}
}

Technical Report:

Save / Share: