Title: {sup 129}I Interlaboratory comparison: phase I and phase II

Abstract

An interlaboratory comparison exercise for {sup 129}I was organized and conducted. Nine laboratories participated in the exercise to either a full or limited extent. In Phase I of the comparison, 11 samples were measured. The suite of samples contained both synthetic ''standard type'' materials (i.e., AgI) and environmental materials. The isotopic {sup 129}I/{sup 127}I ratios of the samples varied from 10{sup {minus}8} to 10{sup {minus}14}. In this phase, each laboratory was responsible for its own chemical preparation of the samples. In Phase I, the {sup 129}I AMS measurements for prepared AgI were in good agreement. However, large discrepancies were seen in {sup 129}I AMS measurements of environmental samples. Because of the large discrepancies seen in the Phase I {sup 129}I intercomparison, a subsequent study was conducted. In Phase II of the {sup 129}I intercomparison, three separate laboratories prepared AgI from two environmental samples (IAEA 375 soil and maples leaves). Each laboratory used its own chemical preparation method with each of the methods being distinctly different. The resulting six samples (two sets of three) were then re-distributed to the participating {sup 129}I AMS facilities and {sup 129}I/{sup 127}I ratios measured. Results and discussion of both the Phase I and Phase IImore » interlaboratory comparison are presented.« less

Authors:
;
Publication Date:
Research Org.:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Org.:
USDOE Office of Defense Programs (DP) (US)
OSTI Identifier:
14662
Report Number(s):
UCRL-JC-128218; YN0100000
YN0100000; TRN: US0106206
DOE Contract Number:  
W-7405-ENG-48
Resource Type:
Conference
Resource Relation:
Conference: 8th International Conference on Accelerator Mass Spectrometry, Vienna (AT), 09/06/1999--09/10/1999; Other Information: PBD: 30 Sep 1999
Country of Publication:
United States
Language:
English
Subject:
37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; 54 ENVIRONMENTAL SCIENCES; IODINE 129; CHEMICAL PREPARATION; INTERLABORATORY COMPARISONS; SOILS; IODINE 127; ISOTOPE RATIO; MASS SPECTROSCOPY; SILVER IODIDES; RADIOECOLOGICAL CONCENTRATION; LEAVES; MAPLES

Citation Formats

Caffee, M W, and Roberts, M L. {sup 129}I Interlaboratory comparison: phase I and phase II. United States: N. p., 1999. Web.
Caffee, M W, & Roberts, M L. {sup 129}I Interlaboratory comparison: phase I and phase II. United States.
Caffee, M W, and Roberts, M L. 1999. "{sup 129}I Interlaboratory comparison: phase I and phase II". United States. https://www.osti.gov/servlets/purl/14662.
@article{osti_14662,
title = {{sup 129}I Interlaboratory comparison: phase I and phase II},
author = {Caffee, M W and Roberts, M L},
abstractNote = {An interlaboratory comparison exercise for {sup 129}I was organized and conducted. Nine laboratories participated in the exercise to either a full or limited extent. In Phase I of the comparison, 11 samples were measured. The suite of samples contained both synthetic ''standard type'' materials (i.e., AgI) and environmental materials. The isotopic {sup 129}I/{sup 127}I ratios of the samples varied from 10{sup {minus}8} to 10{sup {minus}14}. In this phase, each laboratory was responsible for its own chemical preparation of the samples. In Phase I, the {sup 129}I AMS measurements for prepared AgI were in good agreement. However, large discrepancies were seen in {sup 129}I AMS measurements of environmental samples. Because of the large discrepancies seen in the Phase I {sup 129}I intercomparison, a subsequent study was conducted. In Phase II of the {sup 129}I intercomparison, three separate laboratories prepared AgI from two environmental samples (IAEA 375 soil and maples leaves). Each laboratory used its own chemical preparation method with each of the methods being distinctly different. The resulting six samples (two sets of three) were then re-distributed to the participating {sup 129}I AMS facilities and {sup 129}I/{sup 127}I ratios measured. Results and discussion of both the Phase I and Phase II interlaboratory comparison are presented.},
doi = {},
url = {https://www.osti.gov/biblio/14662}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Sep 30 00:00:00 EDT 1999},
month = {Thu Sep 30 00:00:00 EDT 1999}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: