Title: THERMAL FINITE ELEMENT ANALYSIS X9 AND X29 X-RAY RING CROTCH RADIATION ABSORBERS.

Abstract

This report details the efforts by engineers at the National Synchrotron Light Source (NSLS) of Brookhaven National Laboratory (BNL) to evaluate the reliability of water-cooled radiation absorbers used in the NSLS X-ray ring. The absorbers on this report are part of the X-9 and X-29 dipole vacuum chambers. The absorbers are located at the intersection (crotch) of the beamline exit ports with the electron beam chamber, and are generally referred to as ''crotches''. The purpose of this analysis was to demonstrate the thermal reliability of the crotches under operating conditions that will be present over the expected life of the ring. The efforts described include general engineering layouts, engineering calculations, finite element analysis (FEA), results and conclusions of the analysis, and future design recommendations.

Authors:
Publication Date:
Research Org.:
Brookhaven National Lab., Upton, NY (US)
Sponsoring Org.:
USDOE Office of Energy Research (ER) (US)
OSTI Identifier:
14640
Report Number(s):
BNL-66762; KC0204011
R&D Project: LS1; KC0204011; TRN: US0106193
DOE Contract Number:  
AC02-98CH10886
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 11 Aug 1999
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; DESIGN; DIPOLES; ELECTRON BEAMS; NSLS; RELIABILITY; FINITE ELEMENT METHOD; X RADIATION; ENERGY ABSORPTION; RADIATION DOSES

Citation Formats

MERCADO-CORUJO,H. THERMAL FINITE ELEMENT ANALYSIS X9 AND X29 X-RAY RING CROTCH RADIATION ABSORBERS.. United States: N. p., 1999. Web. doi:10.2172/14640.
MERCADO-CORUJO,H. THERMAL FINITE ELEMENT ANALYSIS X9 AND X29 X-RAY RING CROTCH RADIATION ABSORBERS.. United States. doi:10.2172/14640.
MERCADO-CORUJO,H. Wed . "THERMAL FINITE ELEMENT ANALYSIS X9 AND X29 X-RAY RING CROTCH RADIATION ABSORBERS.". United States. doi:10.2172/14640. https://www.osti.gov/servlets/purl/14640.
@article{osti_14640,
title = {THERMAL FINITE ELEMENT ANALYSIS X9 AND X29 X-RAY RING CROTCH RADIATION ABSORBERS.},
author = {MERCADO-CORUJO,H.},
abstractNote = {This report details the efforts by engineers at the National Synchrotron Light Source (NSLS) of Brookhaven National Laboratory (BNL) to evaluate the reliability of water-cooled radiation absorbers used in the NSLS X-ray ring. The absorbers on this report are part of the X-9 and X-29 dipole vacuum chambers. The absorbers are located at the intersection (crotch) of the beamline exit ports with the electron beam chamber, and are generally referred to as ''crotches''. The purpose of this analysis was to demonstrate the thermal reliability of the crotches under operating conditions that will be present over the expected life of the ring. The efforts described include general engineering layouts, engineering calculations, finite element analysis (FEA), results and conclusions of the analysis, and future design recommendations.},