Title: Concomitant ion effects on isotope ratio measurements with liquid sampling – atmospheric pressure glow discharge ion source Orbitrap mass spectrometry

Abstract

With liquid sampling glow discharge-Orbitrap MS, isotope ratio and precision performance improves with rejection of concomitant ion species.

Authors:
ORCiD logo [1]; ORCiD logo [2];  [3];  [3]; ORCiD logo [3]
  1. Department of Chemistry; Clemson University; Clemson; USA; EMSL
  2. Department of Chemistry; Clemson University; Clemson; USA
  3. EMSL; Pacific Northwest National Lab; Richland; USA
Publication Date:
Research Org.:
Pacific Northwest National Laboratory (PNNL), Richland, WA (US), Environmental Molecular Sciences Laboratory (EMSL)
Sponsoring Org.:
USDOE Office of Science (SC), Biological and Environmental Research (BER) (SC-23); USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation (NA-20)
OSTI Identifier:
1438990
Report Number(s):
PNNL-SA-129010
Journal ID: ISSN 0267-9477; JASPE2; 49599; KP1704020
DOE Contract Number:  
AC05-76RL01830
Resource Type:
Journal Article
Journal Name:
Journal of Analytical Atomic Spectrometry
Additional Journal Information:
Journal Volume: 33; Journal Issue: 2; Journal ID: ISSN 0267-9477
Publisher:
Royal Society of Chemistry
Country of Publication:
United States
Language:
English
Subject:
Liquid Sampling-Atmospheric Pressure Glow Discharge; Isotope Ratio; Environmental Molecular Sciences Laboratory

Citation Formats

Hoegg, Edward D., Marcus, R. Kenneth, Hager, George J., Hart, Garret L., and Koppenaal, David W. Concomitant ion effects on isotope ratio measurements with liquid sampling – atmospheric pressure glow discharge ion source Orbitrap mass spectrometry. United States: N. p., 2018. Web. doi:10.1039/c7ja00308k.
Hoegg, Edward D., Marcus, R. Kenneth, Hager, George J., Hart, Garret L., & Koppenaal, David W. Concomitant ion effects on isotope ratio measurements with liquid sampling – atmospheric pressure glow discharge ion source Orbitrap mass spectrometry. United States. doi:10.1039/c7ja00308k.
Hoegg, Edward D., Marcus, R. Kenneth, Hager, George J., Hart, Garret L., and Koppenaal, David W. Mon . "Concomitant ion effects on isotope ratio measurements with liquid sampling – atmospheric pressure glow discharge ion source Orbitrap mass spectrometry". United States. doi:10.1039/c7ja00308k.
@article{osti_1438990,
title = {Concomitant ion effects on isotope ratio measurements with liquid sampling – atmospheric pressure glow discharge ion source Orbitrap mass spectrometry},
author = {Hoegg, Edward D. and Marcus, R. Kenneth and Hager, George J. and Hart, Garret L. and Koppenaal, David W.},
abstractNote = {With liquid sampling glow discharge-Orbitrap MS, isotope ratio and precision performance improves with rejection of concomitant ion species.},
doi = {10.1039/c7ja00308k},
journal = {Journal of Analytical Atomic Spectrometry},
issn = {0267-9477},
number = 2,
volume = 33,
place = {United States},
year = {2018},
month = {1}
}

Works referenced in this record:

Current trends: a perspective from 30 years of Atomic Spectrometry Updates
journal, January 2016

  • Butler, Owen T.; Clough, Robert; Cook, Jennifer M.
  • Journal of Analytical Atomic Spectrometry, Vol. 31, Issue 1
  • DOI: 10.1039/C5JA90056E

Spectroscopic and electrical studies of a solution-cathode glow discharge
journal, January 2005

  • Webb, Michael R.; Andrade, Francisco J.; Gamez, Gerardo
  • Journal of Analytical Atomic Spectrometry, Vol. 20, Issue 11
  • DOI: 10.1039/b503961d

Preliminary Figures of Merit for Isotope Ratio Measurements: The Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Ionization Source Coupled to an Orbitrap Mass Analyzer
journal, April 2016

  • Hoegg, Edward D.; Barinaga, Charles J.; Hager, George J.
  • Journal of The American Society for Mass Spectrometry, Vol. 27, Issue 8
  • DOI: 10.1007/s13361-016-1402-4

Evaluation of the operating parameters of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry
journal, July 2014

  • Zhang, Lynn X.; Manard, Benjamin T.; Kappel, Stefanie Konegger
  • Analytical and Bioanalytical Chemistry, Vol. 406, Issue 29
  • DOI: 10.1007/s00216-014-7990-6

UV/visible Fourier transform spectroscopy using an inductively-coupled plasma: dual-channel noise cancellation
journal, April 1993

  • Travis, J. C.; Winchester, M. R.; Salit, M. L.
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 48, Issue 5
  • DOI: 10.1016/0584-8547(93)80073-4

Performance of an inductively coupled plasma source ion trap mass spectrometer
journal, January 1994

  • Koppenaal, David W.; Barinaga, Charles J.; Smith, Monty R.
  • Journal of Analytical Atomic Spectrometry, Vol. 9, Issue 9
  • DOI: 10.1039/ja9940901053

Liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasmas for diverse spectrochemical analysis applications
journal, January 2017

  • Marcus, R. Kenneth; Manard, Benjamin T.; Quarles, C. Derrick
  • Journal of Analytical Atomic Spectrometry, Vol. 32, Issue 4
  • DOI: 10.1039/C7JA00008A

Orbitrap Mass Spectrometry
journal, May 2013

  • Zubarev, Roman A.; Makarov, Alexander
  • Analytical Chemistry, Vol. 85, Issue 11
  • DOI: 10.1021/ac4001223

Accurate and precise determination of isotopic ratios by MC-ICP-MS: A review
journal, November 2009


Mass shifts and local space charge effects observed in the quadrupole ion trap at higher resolution
journal, May 1995

  • Cox, K. A.; Cleven, C. D.; Cooks, R. G.
  • International Journal of Mass Spectrometry and Ion Processes, Vol. 144, Issue 1-2
  • DOI: 10.1016/0168-1176(95)04152-B

Thermal ionisation mass spectrometry (TIMS) in nuclear science and technology – a review
journal, January 2016


Isotope ratio characteristics and sensitivity for uranium determinations using a liquid sampling-atmospheric pressure glow discharge ion source coupled to an Orbitrap mass analyzer
journal, January 2016

  • Hoegg, Edward D.; Barinaga, Charles J.; Hager, George J.
  • Journal of Analytical Atomic Spectrometry, Vol. 31, Issue 12
  • DOI: 10.1039/C6JA00163G

Space-charge effects on Fourier transform ion cyclotron resonance signals: Experimental observations and three-dimensional trajectory simulations
journal, April 1997


Frontiers of stable isotope geoscience
journal, April 2014


Ion-trap mass spectrometry with an inductively coupled plasma source
journal, January 1994

  • Barinaga, Charles J.; Koppenaal, David W.; McLuckey, Scott A.
  • Rapid Communications in Mass Spectrometry, Vol. 8, Issue 1
  • DOI: 10.1002/rcm.1290080114

Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source for Elemental Mass Spectrometry
journal, April 2011

  • Marcus, R. Kenneth; Quarles, C. Derrick; Barinaga, Charles J.
  • Analytical Chemistry, Vol. 83, Issue 7
  • DOI: 10.1021/ac200098h

High-Resolution Inductively Coupled Plasma Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
journal, September 1997

  • Milgram, K. Eric; White, Forest M.; Goodner, Kevin L.
  • Analytical Chemistry, Vol. 69, Issue 18
  • DOI: 10.1021/ac970126n

Experimental evidence for space-charge effects between ions of the same mass-to-charge in Fourier-transform ion cyclotron resonance mass spectrometry
journal, September 2007

  • Wong, Richard L.; Amster, I. Jonathan
  • International Journal of Mass Spectrometry, Vol. 265, Issue 2-3
  • DOI: 10.1016/j.ijms.2007.01.014

Determination of uranium isotope ratios using a liquid sampling atmospheric pressure glow discharge/Orbitrap mass spectrometer system
journal, August 2017

  • Hoegg, Edward D.; Marcus, R. Kenneth; Koppenaal, David W.
  • Rapid Communications in Mass Spectrometry, Vol. 31, Issue 18
  • DOI: 10.1002/rcm.7937

Liquid sampling–atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry: preliminary parametric evaluation and figures of merit
journal, September 2011

  • Quarles, C. Derrick; Carado, Anthony J.; Barinaga, Charles J.
  • Analytical and Bioanalytical Chemistry, Vol. 402, Issue 1
  • DOI: 10.1007/s00216-011-5359-7

Space charge effects on relative peak heights in fourier transform-ion cyclotron resonance spectra
journal, October 1992


An Atmospheric Pressure Glow Discharge Optical Emission Source for the Direct Sampling of Liquid Media
journal, July 2001

  • Marcus, R. Kenneth; Davis, W. Clay
  • Analytical Chemistry, Vol. 73, Issue 13
  • DOI: 10.1021/ac010158h

Application of mathematical procedures to background correction and multivariate analysis in inductively coupled plasma-optical emission spectrometry
journal, May 1998

  • van Veen, E. H.; de Loos-Vollebregt, M. T. C.
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 53, Issue 5
  • DOI: 10.1016/S0584-8547(98)00109-8

Analysis of molecular isotopic structures at high precision and accuracy by Orbitrap mass spectrometry
journal, November 2017


Performance of Orbitrap Mass Analyzer at Various Space Charge and Non-Ideal Field Conditions: Simulation Approach
journal, February 2012

  • Kharchenko, Andriy; Vladimirov, Gleb; Heeren, Ron M. A.
  • Journal of The American Society for Mass Spectrometry, Vol. 23, Issue 5
  • DOI: 10.1007/s13361-011-0325-3