skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Ultralow energy calibration of LUX detector using Xe 127 electron capture

Abstract

We report an absolute calibration of the ionization yields($$\textit{Q$$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $$^{127}$$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The sequence of gamma-ray and X-ray cascades associated with $$^{127}$$I de-excitations produces clearly identified 2-vertex events in the LUX detector. We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and N- (186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil $$\textit{in situ}$$ measurements that have been explored in liquid xenon.

Authors:
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; more »; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; « less
Publication Date:
Research Org.:
Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
Sponsoring Org.:
USDOE Office of Science (SC), High Energy Physics (HEP) (SC-25)
OSTI Identifier:
1436659
Alternate Identifier(s):
OSTI ID: 1416439
Grant/Contract Number:  
AC02-05CH11231; FG02-11ER41738; AC05-06OR23100; AC52-07NA27344; FG01-91ER40618; FG02-08ER41549; FG02-91ER40674; FG02-91ER40688; FG02-95ER40917; NA0000979; SC0006605; SC0010010; SC0015535; IE120804
Resource Type:
Journal Article: Accepted Manuscript
Journal Name:
Physical Review D
Additional Journal Information:
Journal Volume: 96; Journal Issue: 11; Journal ID: ISSN 2470-0010
Publisher:
American Physical Society (APS)
Country of Publication:
United States
Language:
English

Citation Formats

Akerib, D. S., Alsum, S., Araújo, H. M., Bai, X., Bailey, A. J., Balajthy, J., Beltrame, P., Bernard, E. P., Bernstein, A., Biesiadzinski, T. P., Boulton, E. M., Brás, P., Byram, D., Cahn, S. B., Carmona-Benitez, M. C., Chan, C., Currie, A., Cutter, J. E., Davison, T. J. R., Dobi, A., Druszkiewicz, E., Edwards, B. N., Fallon, S. R., Fan, A., Fiorucci, S., Gaitskell, R. J., Genovesi, J., Ghag, C., Gilchriese, M. G. D., Hall, C. R., Hanhardt, M., Haselschwardt, S. J., Hertel, S. A., Hogan, D. P., Horn, M., Huang, D. Q., Ignarra, C. M., Jacobsen, R. G., Ji, W., Kamdin, K., Kazkaz, K., Khaitan, D., Knoche, R., Larsen, N. A., Lenardo, B. G., Lesko, K. T., Lindote, A., Lopes, M. I., Manalaysay, A., Mannino, R. L., Marzioni, M. F., McKinsey, D. N., Mei, D. -M., Mock, J., Moongweluwan, M., Morad, J. A., Murphy, A. St. J., Nehrkorn, C., Nelson, H. N., Neves, F., O’Sullivan, K., Oliver-Mallory, K. C., Palladino, K. J., Pease, E. K., Rhyne, C., Shaw, S., Shutt, T. A., Silva, C., Solmaz, M., Solovov, V. N., Sorensen, P., Sumner, T. J., Szydagis, M., Taylor, D. J., Taylor, W. C., Tennyson, B. P., Terman, P. A., Tiedt, D. R., To, W. H., Tripathi, M., Tvrznikova, L., Uvarov, S., Velan, V., Verbus, J. R., Webb, R. C., White, J. T., Whitis, T. J., Witherell, M. S., Wolfs, F. L. H., Xu, J., Yazdani, K., Young, S. K., and Zhang, C. Ultralow energy calibration of LUX detector using Xe127 electron capture. United States: N. p., 2017. Web. doi:10.1103/PhysRevD.96.112011.
Akerib, D. S., Alsum, S., Araújo, H. M., Bai, X., Bailey, A. J., Balajthy, J., Beltrame, P., Bernard, E. P., Bernstein, A., Biesiadzinski, T. P., Boulton, E. M., Brás, P., Byram, D., Cahn, S. B., Carmona-Benitez, M. C., Chan, C., Currie, A., Cutter, J. E., Davison, T. J. R., Dobi, A., Druszkiewicz, E., Edwards, B. N., Fallon, S. R., Fan, A., Fiorucci, S., Gaitskell, R. J., Genovesi, J., Ghag, C., Gilchriese, M. G. D., Hall, C. R., Hanhardt, M., Haselschwardt, S. J., Hertel, S. A., Hogan, D. P., Horn, M., Huang, D. Q., Ignarra, C. M., Jacobsen, R. G., Ji, W., Kamdin, K., Kazkaz, K., Khaitan, D., Knoche, R., Larsen, N. A., Lenardo, B. G., Lesko, K. T., Lindote, A., Lopes, M. I., Manalaysay, A., Mannino, R. L., Marzioni, M. F., McKinsey, D. N., Mei, D. -M., Mock, J., Moongweluwan, M., Morad, J. A., Murphy, A. St. J., Nehrkorn, C., Nelson, H. N., Neves, F., O’Sullivan, K., Oliver-Mallory, K. C., Palladino, K. J., Pease, E. K., Rhyne, C., Shaw, S., Shutt, T. A., Silva, C., Solmaz, M., Solovov, V. N., Sorensen, P., Sumner, T. J., Szydagis, M., Taylor, D. J., Taylor, W. C., Tennyson, B. P., Terman, P. A., Tiedt, D. R., To, W. H., Tripathi, M., Tvrznikova, L., Uvarov, S., Velan, V., Verbus, J. R., Webb, R. C., White, J. T., Whitis, T. J., Witherell, M. S., Wolfs, F. L. H., Xu, J., Yazdani, K., Young, S. K., & Zhang, C. Ultralow energy calibration of LUX detector using Xe127 electron capture. United States. doi:10.1103/PhysRevD.96.112011.
Akerib, D. S., Alsum, S., Araújo, H. M., Bai, X., Bailey, A. J., Balajthy, J., Beltrame, P., Bernard, E. P., Bernstein, A., Biesiadzinski, T. P., Boulton, E. M., Brás, P., Byram, D., Cahn, S. B., Carmona-Benitez, M. C., Chan, C., Currie, A., Cutter, J. E., Davison, T. J. R., Dobi, A., Druszkiewicz, E., Edwards, B. N., Fallon, S. R., Fan, A., Fiorucci, S., Gaitskell, R. J., Genovesi, J., Ghag, C., Gilchriese, M. G. D., Hall, C. R., Hanhardt, M., Haselschwardt, S. J., Hertel, S. A., Hogan, D. P., Horn, M., Huang, D. Q., Ignarra, C. M., Jacobsen, R. G., Ji, W., Kamdin, K., Kazkaz, K., Khaitan, D., Knoche, R., Larsen, N. A., Lenardo, B. G., Lesko, K. T., Lindote, A., Lopes, M. I., Manalaysay, A., Mannino, R. L., Marzioni, M. F., McKinsey, D. N., Mei, D. -M., Mock, J., Moongweluwan, M., Morad, J. A., Murphy, A. St. J., Nehrkorn, C., Nelson, H. N., Neves, F., O’Sullivan, K., Oliver-Mallory, K. C., Palladino, K. J., Pease, E. K., Rhyne, C., Shaw, S., Shutt, T. A., Silva, C., Solmaz, M., Solovov, V. N., Sorensen, P., Sumner, T. J., Szydagis, M., Taylor, D. J., Taylor, W. C., Tennyson, B. P., Terman, P. A., Tiedt, D. R., To, W. H., Tripathi, M., Tvrznikova, L., Uvarov, S., Velan, V., Verbus, J. R., Webb, R. C., White, J. T., Whitis, T. J., Witherell, M. S., Wolfs, F. L. H., Xu, J., Yazdani, K., Young, S. K., and Zhang, C. Fri . "Ultralow energy calibration of LUX detector using Xe127 electron capture". United States. doi:10.1103/PhysRevD.96.112011.
@article{osti_1436659,
title = {Ultralow energy calibration of LUX detector using Xe127 electron capture},
author = {Akerib, D. S. and Alsum, S. and Araújo, H. M. and Bai, X. and Bailey, A. J. and Balajthy, J. and Beltrame, P. and Bernard, E. P. and Bernstein, A. and Biesiadzinski, T. P. and Boulton, E. M. and Brás, P. and Byram, D. and Cahn, S. B. and Carmona-Benitez, M. C. and Chan, C. and Currie, A. and Cutter, J. E. and Davison, T. J. R. and Dobi, A. and Druszkiewicz, E. and Edwards, B. N. and Fallon, S. R. and Fan, A. and Fiorucci, S. and Gaitskell, R. J. and Genovesi, J. and Ghag, C. and Gilchriese, M. G. D. and Hall, C. R. and Hanhardt, M. and Haselschwardt, S. J. and Hertel, S. A. and Hogan, D. P. and Horn, M. and Huang, D. Q. and Ignarra, C. M. and Jacobsen, R. G. and Ji, W. and Kamdin, K. and Kazkaz, K. and Khaitan, D. and Knoche, R. and Larsen, N. A. and Lenardo, B. G. and Lesko, K. T. and Lindote, A. and Lopes, M. I. and Manalaysay, A. and Mannino, R. L. and Marzioni, M. F. and McKinsey, D. N. and Mei, D. -M. and Mock, J. and Moongweluwan, M. and Morad, J. A. and Murphy, A. St. J. and Nehrkorn, C. and Nelson, H. N. and Neves, F. and O’Sullivan, K. and Oliver-Mallory, K. C. and Palladino, K. J. and Pease, E. K. and Rhyne, C. and Shaw, S. and Shutt, T. A. and Silva, C. and Solmaz, M. and Solovov, V. N. and Sorensen, P. and Sumner, T. J. and Szydagis, M. and Taylor, D. J. and Taylor, W. C. and Tennyson, B. P. and Terman, P. A. and Tiedt, D. R. and To, W. H. and Tripathi, M. and Tvrznikova, L. and Uvarov, S. and Velan, V. and Verbus, J. R. and Webb, R. C. and White, J. T. and Whitis, T. J. and Witherell, M. S. and Wolfs, F. L. H. and Xu, J. and Yazdani, K. and Young, S. K. and Zhang, C.},
abstractNote = {We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The sequence of gamma-ray and X-ray cascades associated with $^{127}$I de-excitations produces clearly identified 2-vertex events in the LUX detector. We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and N- (186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil $\textit{in situ}$ measurements that have been explored in liquid xenon.},
doi = {10.1103/PhysRevD.96.112011},
journal = {Physical Review D},
number = 11,
volume = 96,
place = {United States},
year = {Fri Dec 01 00:00:00 EST 2017},
month = {Fri Dec 01 00:00:00 EST 2017}
}

Journal Article:
Free Publicly Available Full Text
This content will become publicly available on December 1, 2018
Publisher's Version of Record

Citation Metrics:
Cited by: 1 work
Citation information provided by
Web of Science

Save / Share: