Title: X-Ray Phase Contrast Imaging (XPCI) System

Abstract

Sandia National Laboratories (Sandia) and Carestream Health, Inc. (CHI) collaborated on the development of a grating-based X-ray Phase Contrast Imaging (XPCI) system at Sandia. The purpose of the agreement was to share research and development knowledge, resources, and capabilities in the advancement of XPCI that would be mutually beneficial to CHI and Sandia. In the course of this agreement Sandia designed and built an XPCI apparatus including opto-mechanical design, source and x-ray detector selection, software interface, hardware assembly, and system alignment. Data acquisition and image reconstruction were demonstrated at both CHI and Sandia. XPCI is a new imaging modality that enables non-destructive inspection of low density materials not previously possible with conventional x-ray. The technique fills a capability gap valuable to both the industry partner in their technical portfolio and in national security applications important to Sandia and the DOE mission space.

Authors:
 [1]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Publication Date:
Research Org.:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Sponsoring Org.:
USDOE National Nuclear Security Administration (NNSA)
OSTI Identifier:
1433789
Report Number(s):
SAND-2018-3937R
662332
DOE Contract Number:  
AC04-94AL85000
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English

Citation Formats

Weiss, Gregory Victor Allen. X-Ray Phase Contrast Imaging (XPCI) System. United States: N. p., 2018. Web. doi:10.2172/1433789.
Weiss, Gregory Victor Allen. X-Ray Phase Contrast Imaging (XPCI) System. United States. doi:10.2172/1433789.
Weiss, Gregory Victor Allen. Sun . "X-Ray Phase Contrast Imaging (XPCI) System". United States. doi:10.2172/1433789. https://www.osti.gov/servlets/purl/1433789.
@article{osti_1433789,
title = {X-Ray Phase Contrast Imaging (XPCI) System},
author = {Weiss, Gregory Victor Allen},
abstractNote = {Sandia National Laboratories (Sandia) and Carestream Health, Inc. (CHI) collaborated on the development of a grating-based X-ray Phase Contrast Imaging (XPCI) system at Sandia. The purpose of the agreement was to share research and development knowledge, resources, and capabilities in the advancement of XPCI that would be mutually beneficial to CHI and Sandia. In the course of this agreement Sandia designed and built an XPCI apparatus including opto-mechanical design, source and x-ray detector selection, software interface, hardware assembly, and system alignment. Data acquisition and image reconstruction were demonstrated at both CHI and Sandia. XPCI is a new imaging modality that enables non-destructive inspection of low density materials not previously possible with conventional x-ray. The technique fills a capability gap valuable to both the industry partner in their technical portfolio and in national security applications important to Sandia and the DOE mission space.},
doi = {10.2172/1433789},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sun Apr 01 00:00:00 EDT 2018},
month = {Sun Apr 01 00:00:00 EDT 2018}
}

Technical Report:

Save / Share: