Industrialization of the nitrogen-doping preparation for SRF cavities for LCLS-II
The Linac Coherent Light Source II (LCLS-II) is a new state-of-the-art coherent X-ray source being constructed at SLAC National Accelerator Laboratory. It employs 280 superconducting radio frequency (SRF) cavities in order operate in continuous wave (CW) mode. To reduce the overall cryogenic cost of such a large accelerator, nitrogen-doping of the SRF cavities is being used. Nitrogen-doping has consistently been shown to increase the efficiency of SRF cavities operating in the 2.0 K regime and at medium fields (15–20 MV/m) in vertical cavity tests and horizontal cryomodule tests. While nitrogen-doping’s efficacy for improvement of cavity performance was demonstrated at three independent labs, Fermilab, Jefferson Lab, and Cornell University, transfer of the technology to industry for LCLS-II production was not without challenges. Here we present results from the beginning of LCLS-II cavity production. We discuss qualification of the cavity vendors and the first cavities from each vendor. Finally, we demonstrate that nitrogen-doping has been successfully transferred to SRF cavity vendors, resulting in consistent production of cavities with better cryogenic efficiency than has ever been achieved for a large-scale accelerator.
- Research Organization:
- SLAC National Accelerator Laboratory (SLAC), Menlo Park, CA (United States); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), High Energy Physics (HEP)
- Grant/Contract Number:
- AC02-76F00515; AC02-76SF00515; AC02-07CH11359
- OSTI ID:
- 1457217
- Alternate ID(s):
- OSTI ID: 1417625; OSTI ID: 1430659
- Report Number(s):
- FERMILAB-PUB-17-660-TD; S0168900217312767; PII: S0168900217312767
- Journal Information:
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Vol. 883 Journal Issue: C; ISSN 0168-9002
- Publisher:
- ElsevierCopyright Statement
- Country of Publication:
- Netherlands
- Language:
- English
Web of Science
Error analysis for intrinsic quality factor measurement in superconducting radio frequency resonators
|
journal | December 2014 |
Production of superconducting 1.3-GHz cavities for the European X-ray Free Electron Laser
|
journal | September 2016 |
Nitrogen-doped 9-cell cavity performance in a test cryomodule for LCLS-II
|
journal | January 2015 |
Efficient expulsion of magnetic flux in superconducting radiofrequency cavities for high Q 0 applications
|
journal | June 2016 |
Superconducting TESLA cavities
|
journal | September 2000 |
Similar Records
The Transfer of Improved Cavity Processing Protocols to Industry for LCLS-II: N-Doping and Electropolishing
High Precision RF Control for SRF Cavities in LCLS-II