skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: The electro-thermal stability of tantalum relative to aluminum and titanium in cylindrical liner ablation experiments at 550 kA

Authors:
ORCiD logo [1];  [1];  [1];  [2];  [2]; ORCiD logo [1];  [1];  [1]; ORCiD logo [1]
  1. Plasma, Pulsed Power and Microwave Laboratory, Nuclear Engineering and Radiological Sciences Department, University of Michigan, Ann Arbor, Michigan 48109-21041, USA
  2. Sandia National Laboratories, Albuquerque, New Mexico 87185, USA
Publication Date:
Sponsoring Org.:
USDOE
OSTI Identifier:
1423401
Grant/Contract Number:  
NA0001984; SC0012328; NA0003525
Resource Type:
Journal Article: Publisher's Accepted Manuscript
Journal Name:
Physics of Plasmas
Additional Journal Information:
Journal Name: Physics of Plasmas Journal Volume: 25 Journal Issue: 3; Journal ID: ISSN 1070-664X
Publisher:
American Institute of Physics
Country of Publication:
United States
Language:
English

Citation Formats

Steiner, Adam M., Campbell, Paul C., Yager-Elorriaga, David A., Cochrane, Kyle R., Mattsson, Thomas R., Jordan, Nicholas M., McBride, Ryan D., Lau, Y. Y., and Gilgenbach, Ronald M.. The electro-thermal stability of tantalum relative to aluminum and titanium in cylindrical liner ablation experiments at 550 kA. United States: N. p., 2018. Web. doi:10.1063/1.5012891.
Steiner, Adam M., Campbell, Paul C., Yager-Elorriaga, David A., Cochrane, Kyle R., Mattsson, Thomas R., Jordan, Nicholas M., McBride, Ryan D., Lau, Y. Y., & Gilgenbach, Ronald M.. The electro-thermal stability of tantalum relative to aluminum and titanium in cylindrical liner ablation experiments at 550 kA. United States. doi:10.1063/1.5012891.
Steiner, Adam M., Campbell, Paul C., Yager-Elorriaga, David A., Cochrane, Kyle R., Mattsson, Thomas R., Jordan, Nicholas M., McBride, Ryan D., Lau, Y. Y., and Gilgenbach, Ronald M.. Thu . "The electro-thermal stability of tantalum relative to aluminum and titanium in cylindrical liner ablation experiments at 550 kA". United States. doi:10.1063/1.5012891.
@article{osti_1423401,
title = {The electro-thermal stability of tantalum relative to aluminum and titanium in cylindrical liner ablation experiments at 550 kA},
author = {Steiner, Adam M. and Campbell, Paul C. and Yager-Elorriaga, David A. and Cochrane, Kyle R. and Mattsson, Thomas R. and Jordan, Nicholas M. and McBride, Ryan D. and Lau, Y. Y. and Gilgenbach, Ronald M.},
abstractNote = {},
doi = {10.1063/1.5012891},
journal = {Physics of Plasmas},
number = 3,
volume = 25,
place = {United States},
year = {Thu Mar 01 00:00:00 EST 2018},
month = {Thu Mar 01 00:00:00 EST 2018}
}

Journal Article:
Free Publicly Available Full Text
This content will become publicly available on March 1, 2019
Publisher's Accepted Manuscript

Save / Share:

Works referenced in this record:

Ab initiomolecular dynamics for liquid metals
journal, January 1993