Lujan Center Mark-IV Target Neutronics Design Internal Review Report
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
- Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
The 1L Target Moderator Reflector System (TMRS) at the Lujan Center will need to be replaced before the CY 2020 operating cycle. A Physics Division design team investigated options for improving the overall target performance for nuclear science research with minimal reduction in performance for materials science. This review concluded that devoting an optimized arrangement of the Lujan TMRS upper tier to nuclear science and using the lower tier for materials science can achieve those goals. This would open the opportunity for enhanced nuclear science research in an important neutron energy range for NNSA. There will be no other facility in the US that will compete in the keV energy range provided flight paths and instrumentation are developed to take advantage of the neutron flux and resolution.
- Research Organization:
- Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC52-06NA25396
- OSTI ID:
- 1422976
- Report Number(s):
- LA-UR-18-21466
- Country of Publication:
- United States
- Language:
- English
Similar Records
Physics design of the next-generation spallation neutron target-moderator-reflector-shield assembly at LANSCE