Sensitivity Analysis and Requirements for Temporally and Spatially Resolved Thermometry Using Neutron Resonance Spectroscopy
Abstract
This report is intended to examine the use of neutron resonance spectroscopy (NRS) to make time- dependent and spatially-resolved temperature measurements of materials in extreme conditions. Specifically, the sensitivities of the temperature estimate on neutron-beam and diagnostic parameters is examined. Based on that examination, requirements are set on a pulsed neutron-source and diagnostics to make a meaningful measurement.
- Authors:
-
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
- Publication Date:
- Research Org.:
- Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
- Sponsoring Org.:
- USDOE National Nuclear Security Administration (NNSA), Office of Defense Programs (DP)
- OSTI Identifier:
- 1419717
- Report Number(s):
- LA-UR-18-20686
- DOE Contract Number:
- AC52-06NA25396
- Resource Type:
- Technical Report
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 36 MATERIALS SCIENCE; 47 OTHER INSTRUMENTATION
Citation Formats
Fernandez, Juan Carlos, Barnes, Cris William, Mocko, Michael Jeffrey, and Zavorka, Lukas. Sensitivity Analysis and Requirements for Temporally and Spatially Resolved Thermometry Using Neutron Resonance Spectroscopy. United States: N. p., 2018.
Web. doi:10.2172/1419717.
Fernandez, Juan Carlos, Barnes, Cris William, Mocko, Michael Jeffrey, & Zavorka, Lukas. Sensitivity Analysis and Requirements for Temporally and Spatially Resolved Thermometry Using Neutron Resonance Spectroscopy. United States. https://doi.org/10.2172/1419717
Fernandez, Juan Carlos, Barnes, Cris William, Mocko, Michael Jeffrey, and Zavorka, Lukas. 2018.
"Sensitivity Analysis and Requirements for Temporally and Spatially Resolved Thermometry Using Neutron Resonance Spectroscopy". United States. https://doi.org/10.2172/1419717. https://www.osti.gov/servlets/purl/1419717.
@article{osti_1419717,
title = {Sensitivity Analysis and Requirements for Temporally and Spatially Resolved Thermometry Using Neutron Resonance Spectroscopy},
author = {Fernandez, Juan Carlos and Barnes, Cris William and Mocko, Michael Jeffrey and Zavorka, Lukas},
abstractNote = {This report is intended to examine the use of neutron resonance spectroscopy (NRS) to make time- dependent and spatially-resolved temperature measurements of materials in extreme conditions. Specifically, the sensitivities of the temperature estimate on neutron-beam and diagnostic parameters is examined. Based on that examination, requirements are set on a pulsed neutron-source and diagnostics to make a meaningful measurement.},
doi = {10.2172/1419717},
url = {https://www.osti.gov/biblio/1419717},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Jan 31 00:00:00 EST 2018},
month = {Wed Jan 31 00:00:00 EST 2018}
}
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.